12 SPARC Enterprise T5120 and T5220 Servers Product Notes October 2007
Though no error or fault is reported, it is easy to identify due to the fact that when
this problem is encountered, no PCIe I/O devices will be available to the system. If
you power-on the system or reset the domain and try and boot from a disk or
network device and you get an error similar to the following:
At the OpenBoot prompt issue the command show-devs. Check the output to for
PCIe devices. If there are no devices then you have encountered this problem.
Note – All PCIe devices begin with the path /pci@0/pci@0.
Corrective Action:
If this problem is encountered you should take down all domains and power off the
system. Next run Power On Self Test (POST) to identify whether this is a persistent
failure or not.
To enable POST use the SP ALOM CMT compatibility CLI command setsc and
enable POST to run at max level.
For example:
Next, power on the system and POST will execute testing the CPU, Memory and IO
sub-systems. If the problem is persistent POST will fail the PCIe root complex and
disable the component /SYS/MB/PCIE.
If POST does detect the problem, the system's motherboard will need to be replaced.
Please contact your sales representative to schedule a motherboard replacement.
Diagnosed FBR and FBU Errors to Branch (CR 6536482)
Currently, cpummem de does not diagnose the fbr/fbu errors.
{0} ok boot disk
Boot device: /pci@0/pci@0/pci@2/scsi@0/disk@0 File and args:
ERROR: boot-read fail
Can't locate boot device
{0} ok
sc> setsc diag_mode normal
sc> setsc diag_level max