C122-H004-07EN FUJITSU Server PRIMEQUEST 1000 Series Hardware Installation Manual

Strona 2

- The PDF file of this manual is intended for display using Adobe® Reader® in single page viewing mode at100% zoom.- The PRIMEQUEST 1800E2/1800E model

Strona 3 - For Safe Operation

PRIMEQUEST 1000 Series Hardware Installation ManualAPPENDIX A Racks80 C122-H004-07EN

Strona 4 - Organization of this manual

APPENDIX B UPC Interface This appendix describes the UPC interface that can be used with thePRIMEQUEST 1000 series. B.1 Overview ...

Strona 5 - Related manuals

B.1 OverviewThe CVCF provides a stable power supply to the system even in the event of a power abnormality or major poweroutage.Through a connection

Strona 6

B.2 Signal CableFor the signal cable, use a shielded-pair cable that satisfies the following specifications.- Direct current resistance (round trip/o

Strona 7 - Abbreviations

B.3 Connection of Main Unit and CVCF and Signal Line DefinitionsThis section shows the connection of the main unit and CVCF. This section also provid

Strona 8 - Notation

Signal name Pin FunctionThe length of the time from when the *ACOFF signal goes ON to when shutdownprocessing actually starts can be specified from th

Strona 9 - Product operating environment

B.4 Cable ConnectorThis section describes the connector type and the correspondence between the UPC interface and the signal cablepins. Connector typ

Strona 10 - Safety Precautions

Index[Numbers]100 to 120 V configuration (primary power feed, noredundant power supply)... 37100 to 12

Strona 11

Outline Drawings of the Devices... 3Overview...

Strona 13 - Support and service

* The label is affixed at either location.Warning label location (PRIMEQUEST 1800E2/1800E rear) Warning label location (PRIMEQUEST 1800E2/1800E rear)

Strona 14 - Revision History

Warning label location (PCI_Box) Notes on Handling the ProductAdding optional productsFor stable operation of the PRIMEQUEST 1000 series server, use o

Strona 15 - Contents

- Unpacking an optional Fujitsu product, such as an optional adapter, delivered tothe customer Modifying or recycling the productModifying this produc

Strona 16

https://www-s.fujitsu.com/global/contact/computing/PRMQST_feedback.html WarrantyIf a component failure occurs during the warranty period, we will repa

Strona 17

ContentsCHAPTER 1 Installation Information ...

Strona 18

B.4 Cable Connector ...

Strona 19

FiguresWarning label location (PRIMEQUEST 1800E2/1800E rear) ... ixWarning l

Strona 20

FIGURE A.17 Outline drawing of the 19-inch rack Model 1624 (base/without stabilizer) ... 73FIGURE A.18 Outline drawing o

Strona 21

TablesTABLE 1.1 Device names and configuration details ... 2TA

Strona 23 - 3 C122-H004-07EN

PRIMEQUEST 1000 Series Hardware Installation ManualTablesxviii C122-H004-07EN

Strona 24 - PCI_Box front view

CHAPTER 1 Installation Information This chapter provides various useful information on PRIMEQUEST1000 series installation. The information includes d

Strona 25 - PCI_Box right side view

1.1 Device Configuration DetailsTABLE 1.1 Device names and configuration details lists device names and configuration details. TABLE 1.1 Device names

Strona 26 - 6 C122-H004-07EN

1.2 Outline Drawings of the DevicesThis section provides outline drawings of each device. - 1.2.1 PRIMEQUEST 1800E2/1800E outline drawings- 1.2.2 PCI

Strona 27 - 7 C122-H004-07EN

PRIMEQUEST 1800E2/1800E (top view) FIGURE 1.3 PRIMEQUEST 1800E2/1800E (top view) PRIMEQUEST 1800E2/1800E (right side view) FIGURE 1.4 PRIMEQUEST 18

Strona 28 - 8 C122-H004-07EN

FIGURE 1.5 PCI_Box front view PCI_Box rear view FIGURE 1.6 PCI_Box rear view PCI_Box top view FIGURE 1.7 PCI_Box top view PCI_Box right side view F

Strona 29 - 9 C122-H004-07EN

1.3 Installation SpecificationsThis section lists the installation specifications of each device. - 1.3.1 PRIMEQUEST 1800E2 installation specificatio

Strona 30 - 10 C122-H004-07EN

Item DescriptionMaximumpowerconsumption/apparentpowerOperating Input voltage: 200 V 4.00 kW / 4.21 kVAStandby Input voltage: 200 V 95 W / 126 VAPower

Strona 31 - 1.4 Installation Area

Item DescriptionWeight [kg (lb)] (*2) 150 (330)Air conditioningrequirementsMaximum heat output [kJ/h (BTU/h)] 14,400 (13,649)Exhaust airflow [m3/min(f

Strona 32 - 12 C122-H004-07EN

- A = Number of mounted SBs (1 to 4)- B = Number of mounted IO Units (1 or 2)- C = Number of mounted expansion power supply units (0 to 2)*3 If the in

Strona 33 - (2) Front of the device

PrefaceThis manual describes the specifications and installation location requirements of PRIMEQUEST 1000 seriesinstallation. The manual is intended f

Strona 34 - 14 C122-H004-07EN

Item DescriptionNoise [dB] (Included in mainunit specifications)Acoustic power level [B] (Included in mainunit specifications)Allowable vibration[m/s2

Strona 35 - 15 C122-H004-07EN

1.4 Installation AreaThis section shows the installation area and service areas of the PRIMEQUEST 1000 series and PCI_Box. Thediagrams assume that th

Strona 36 - 1.6 Installation Environment

No. Description(1) Service area(2) Front of the deviceFIGURE 1.10 Service area with the 19-inch rack model 1640 (19R-164xx) installed PRIMEQUEST 1000

Strona 37 - 1.6.3 Seawater (salt damage)

No. Description(1) Service area(2) Front of the deviceFIGURE 1.11 Service area with the 19-inch rack model 1624 (19R-162xx) installedPRIMEQUEST 1000

Strona 38 - 1.7 Security Actions

1.5 Cooling and Exhaust Air Flows in the DevicesThis section shows the cooling and exhaust air flows in each device. - 1.5.1 Cooling and exhaust air

Strona 39

1.5.2 Cooling and exhaust air flows in the PCI_Box No. Description(1) Air intake(2) Exhaust air(3) Exhaust ventFIGURE 1.13 Cooling and exhaust air fl

Strona 40 - 2.1 Overview of Connections

1.6 Installation EnvironmentThis section describes matters regarding the installation environment of equipment. - 1.6.1 Dust- 1.6.2 Corrosive gases-

Strona 41 - 21 C122-H004-07EN

1.6.3 Seawater (salt damage)The air in the vicinity of coastal areas contains large amounts of airborne sea salt particles. If these particles remain

Strona 42 - 22 C122-H004-07EN

1.7 Security ActionsFor details on security actions, see "CHAPTER 8 Security Actions" in the SPARCEnterprise/PRIMEQUEST Common Installation

Strona 43 - 2.2 Signal Cable Connections

CHAPTER 2 Connection Information This chapter describes the cables used with the PRIMEQUEST 1000series and provides an overview of cable connections.

Strona 44 - List of cables

- Trademarks Organization of this manualThis manual is organized as follows.CHAPTER 1 Installation InformationChapter 1 provides various useful inform

Strona 45 - Cable connection diagram

2.1 Overview of ConnectionsThis section describes an overview of connections for the PRIMEQUEST 1000 series. 2.1.1 Overview of Connections (PRIMEQUE

Strona 46

Number inFigure 2.1Component Description*3 GSPB PRIMEQUEST 1800E2 Up to 2 units can bemounted.*4 MMB PRIMEQUEST 1800E2 Up to 2 units can bemounted.*5

Strona 47 - 27 C122-H004-07EN

TABLE 2.2 Notes on device connections (PRIMEQUEST 1800E)Number inFigure 2.2Component Description*1 System board PRIMEQUEST 1800E Up to 4 units can bem

Strona 48 - 28 C122-H004-07EN

2.2 Signal Cable ConnectionsThis section provides a cable connection diagram and a list of signal cables. The section also describes dos anddon'

Strona 49 - 29 C122-H004-07EN

- The numbers in parentheses ( ) correspond to the cable numbers in TABLE 2.3 Cables (for the basic interfacesand peripheral devices) (PRIMEQUEST 1800

Strona 50 - 30 C122-H004-07EN

No. Name Model name Commercially available types LengthCBL-MLLC40 40 mCBL-MLLC50 50 mCBL-MLLD1A Sold separately: 100 m (with cableinsulation)Dual LC c

Strona 51 - (2) PCI Express interface #0

FIGURE 2.4 Interface cable connections (for the basic interfaces and peripheral devices) (PRIMEQUEST1800E) RemarksThe numbers in parentheses ( ) cor

Strona 52 - 2.3 Power Cable Connections

No. Name Model name Commercially available types LengthTPCBL-B100 100 m(2) Enhanced Category 5UTP cableTPCBL-C005 Sold separately: Select from lengths

Strona 53 - Dual power feed configuration

No. Name Model name Commercially available types LengthCBL-MLSC40 40 mCBL-MLSC50 50 mCBL-MLSA1A Sold separately: 100 m (with cableinsulation)Dual LC c

Strona 54 - 34 C122-H004-07EN

FIGURE 2.6 External interface connectors in the PRIMEQUEST 1800E2/1800E main unit (rear view) MMB external interfaces in detailFIGURE 2.7 MMB externa

Strona 55 - 35 C122-H004-07EN

Title Description Manual codeSPARC Enterprise/PRIMEQUEST CommonInstallation PlanningManualProvides the necessary information and concepts youshould un

Strona 56 - 36 C122-H004-07EN

FIGURE 2.8 IOB external interfaces in detail GSPB external interfaces in detailFIGURE 2.9 GSPB external interfaces in detail PCI_Box external interfac

Strona 57 - 37 C122-H004-07EN

No. Description(1) PCI Express interface #1(2) PCI Express interface #0FIGURE 2.10 PCI_Box external interfaces in detail PRIMEQUEST 1000 Series Hardwa

Strona 58 - 2.4.2 PCI_Box

2.3 Power Cable ConnectionsThis section shows diagrams of the input power distribution for the PRIMEQUEST 1000 series main unit and thePCI_Box. - 2.3

Strona 59 - 39 C122-H004-07EN

FIGURE 2.12 Redundant power supply configuration (primary power feed, redundant power supply) *1 Power cables (AC#0 to AC#2) are connected to PSUs (PS

Strona 60 - 40 C122-H004-07EN

2.3.2 Power cable connections of the PCI_BoxThis section shows diagrams of the input power distribution for the PCI_Box. RemarksUse the same power co

Strona 61 - 41 C122-H004-07EN

FIGURE 2.15 200 to 240 V redundant power supply configuration (primary power feed, redundant powersupply) *1 Power cables (AC#0 to AC#1) are connected

Strona 62 - 42 C122-H004-07EN

FIGURE 2.16 200 to 240 V dual power feed configuration *1 Power cables (AC#0 to AC#1) are connected to PSUs (PSU#0 to PSU#1) on a one-to-one basis.*2

Strona 63 - Installing the Product

FIGURE 2.17 100 to 120 V configuration (primary power feed, no redundant power supply) *1 The power cable (AC#0) is connected to the PSU (PSU#0) on a

Strona 64 - 3.1 Elevator Load Conditions

2.4 Input Power Connection SpecificationsThis section lists the specifications of input power connections. - 2.4.1 PRIMEQUEST 1000 series main unit-

Strona 65 - 45 C122-H004-07EN

2.4.3 Connections between the power distribution box and distribution panelTABLE 2.7 Specifications of the power cable between the power distribution

Strona 66 - 46 C122-H004-07EN

Title Description Manual codeServerView SuiteServerView OperationsManager Quick Installation(Windows)Describes how to install and start ServerViewOper

Strona 67 - APPENDIX A Racks

2.5 Power Cable Connections under a Raised Floor (Except inEurope)For a power distribution box (or the main unit or the PCI_Box) whose power cable is

Strona 68 - A.1 Rack Mounting

2.6 Shutoff Characteristic of the Customer's Distribution Panel(Only When Connected to the Power Distribution Box)To protect the device when it

Strona 69 - 49 C122-H004-07EN

FIGURE 2.20 Distribution panel breaker characteristicsPRIMEQUEST 1000 Series Hardware Installation ManualCHAPTER 2 Connection Information42 C122-H004-

Strona 70 - 50 C122-H004-07EN

CHAPTER 3 Notes on Carrying In andInstalling the Product This chapter provides notes on carrying in and installing thePRIMEQUEST 1000 series server.

Strona 71 - 51 C122-H004-07EN

3.1 Elevator Load ConditionsThe rack with the device mounted is wider than the average computer. Therefore, to use an elevator to carry in therack, t

Strona 72 - Rack mounting requirements

3.2 Earthquake Preparedness MeasuresThe purpose of the earthquake preparedness measures is to prevent the computer from falling and breaking, and toe

Strona 73 - 53 C122-H004-07EN

PRIMEQUEST 1000 Series Hardware Installation ManualCHAPTER 3 Notes on Carrying In and Installing the Product46 C122-H004-07EN

Strona 74 - 54 C122-H004-07EN

APPENDIX A Racks This appendix provides various information on the mounting racks forthe PRIMEQUEST 1000 series and PCI_Box. A.1 Rack Mounting ...

Strona 75 - 55 C122-H004-07EN

A.1 Rack MountingThe PRIMEQUEST 1000 series (including peripheral devices) has been developed and its operation guaranteedwith the basic assumption t

Strona 76 - 56 C122-H004-07EN

(1)Considerearthquake-resistantanchoring for rackinstallation.(2)Select a rack. (3)Select a fixedconstruction. (4)Arrange for anoptionalearthquake-res

Strona 77 - Conditions of rack depth

Title Description Manual codeThe Fujitsu Technology Solutions manuals serverhttp://manuals.ts.fujitsu.com/index.php?id=0MegaRAID SAS DeviceDriver Inst

Strona 78 - 58 C122-H004-07EN

(2) Select a rack.For a rack to be fixed in place, select one that comes without a stabilizer. See "(3) Select a fixed construction"below.Fo

Strona 79 - Other conditions

A.2 Rack Mounting RequirementsThis section describes rack mounting requirements. - A.2.1 Requirements for mounting in a Fujitsu 19-inch rack- A.2.2 R

Strona 80 - A.3 Fujitsu 19-inch Racks

TABLE A.2 Recommended racks for mountingFujitsu 19-inch rack Depth (mm) Open area ratioModel 2742 1050 80%Model 2737 1050 80%Model 2724 1050 80%Model

Strona 81 - 61 C122-H004-07EN

*: For the models 2742/2737/2724/2642/2624/2616, the bottom of the mounted device must not be below2U. It is not mountable at 1U of the lowest rack.Fo

Strona 82 - 62 C122-H004-07EN

No. Description(3) PRIMEQUEST 1800E2/1800E cabinet (12U)(4) PRIMEQUEST 1800E2/1800E lower limitposition (1U)FIGURE A.2 Rack mounting requirements (PRI

Strona 83 - 63 C122-H004-07EN

No. Description(1) PRIMEQUEST 1800E2/1800ELocations of the cable holders to be removed(Both sides of the (upper) front cover)FIGURE A.3 Cable holder

Strona 84 - 64 C122-H004-07EN

Procedure for removing cable holders (Model 1740)Remove the cable holders by using a Phillips screwdriver. No. Description(1) M5 screw(2) Cable holde

Strona 85 - 65 C122-H004-07EN

No. Description(1) Cable holder(2) Machine screw (SEMS w/washer screw M5 x 12)FIGURE A.5 Removing a cable holder (Model 1640/Model 1624) A.2.2 Requ

Strona 86 - 66 C122-H004-07EN

The device is mounted in a rack using a rack mounting kit (supplied with the PRIMEQUEST 1000 series server).Therefore, the following conditions regard

Strona 87 - 67 C122-H004-07EN

FIGURE A.7 Conditions regarding rack posts A: Space for attaching the device front panel: 483 mm (19.0 in.) or moreB: Distance between holes on the le

Strona 88 - 68 C122-H004-07EN

Formal product name AbbreviationMicrosoft® Windows Server® 2008 Standard WindowsWindows Server 2008Microsoft® Windows Server® 2008 EnterpriseMicrosoft

Strona 89 - 69 C122-H004-07EN

A.3 Fujitsu 19-inch RacksThis section shows the types, outline drawings, and bottom view drawings of Fujitsu 19-inch racks. - A.3.1 Types of 19-inch

Strona 90 - (3) Right side view

ItemNo.Model name Product name Width(*1)Depth(*1)Height(*1)Totalweightcapacity(*2)(*3)Rackweight(*2)Totalrackweight(*2)Remarks(expansion/withoutstabil

Strona 91 - 71 C122-H004-07EN

ItemNo.Model name Product name Width(*1)Depth(*1)Height(*1)Totalweightcapacity(*2)(*3)Rackweight(*2)Totalrackweight(*2)Remarks(expansion/withstabilize

Strona 92 - 72 C122-H004-07EN

No. Description(1) Top view(2) Rear view(3) Right side view(4) Front view(5) Stabilizer(6) Top coverFIGURE A.8 Outline drawing of the 19-inch rack Mo

Strona 93 - 73 C122-H004-07EN

19-inch rack Model 1740 (base/without stabilizer) No. Description(1) Top view(2) Rear view(3) Right side view(4) Front viewFIGURE A.9 Outline drawing

Strona 94 - 74 C122-H004-07EN

PRIMEQUEST 1000 Series Hardware Installation ManualAPPENDIX A Racks65 C122-H004-07EN

Strona 95 - 75 C122-H004-07EN

No. Description(1) Top view(2) Rear view(3) Right side view(4) Front view(5) Bottom view(6) Leveling foot(7) CasterFIGURE A.10 Outline drawing of the

Strona 96 - 76 C122-H004-07EN

No. Description(1) Top view(2) Rear view(3) Right side view(4) Front viewFIGURE A.11 Outline drawing of the 19-inch rack Model 1740 (expansion/withou

Strona 97 - 77 C122-H004-07EN

No. Description(1) Top view(2) Rear view(3) Right side view(4) Front view(5) Stabilizer(6) Top coverFIGURE A.12 Outline drawing of the 19-inch rack Mo

Strona 98 - 78 C122-H004-07EN

No. Description(1) Top view(2) Rear view(3) Right side view(4) Front viewFIGURE A.13 Outline drawing of the 19-inch rack Model 1640 (base/without stab

Strona 99 - 79 C122-H004-07EN

Notes on notations- In this manual, the Management Board and MMB firmware are abbreviated as "MMB."- In this manual, IOBs and GSPBs (LIOBs a

Strona 100 - 80 C122-H004-07EN

No. Description(1) Top view(2) Rear view(3) Right side viewPRIMEQUEST 1000 Series Hardware Installation ManualAPPENDIX A Racks70 C122-H004-07EN

Strona 101 - APPENDIX B UPC Interface

No. Description(4) Front view(5) Bottom view(6) Leveling foot(7) CasterFIGURE A.14 Outline drawing of the 19-inch rack Model 1640 (expansion/with stab

Strona 102 - B.1 Overview

No. Description(2) Rear view(3) Right side view(4) Front viewFIGURE A.15 Outline drawing of the 19-inch rack Model 1640 (expansion/without stabilizer)

Strona 103 - B.2 Signal Cable

No. Description(6) Top coverFIGURE A.16 Outline drawing of the 19-inch rack Model 1624 (base/with stabilizer) 19-inch rack Model 1624 (base/without st

Strona 104 - 84 C122-H004-07EN

No. Description(1) Top view(2) Rear view(3) Right side view(4) Front view(5) Bottom view(6) Leveling foot(7) CasterFIGURE A.18 Outline drawing of the

Strona 105 - 85 C122-H004-07EN

19-inch rack Model 1624 (expansion/without stabilizer) No. Description(1) Top view(2) Rear view(3) Right side view(4) Front viewFIGURE A.19 Outline d

Strona 106 - B.4 Cable Connector

Bottom view drawing of the rack equipped with the pullout stabilizer (standard type only)Bottom view drawing of connected 19-inch racks (standard)Bott

Strona 107

FIGURE A.21 Bottom view drawing of the (slim) 19-inch rack Bottom view drawing of the rack equipped with the pullout stabilizer (standard type only)PR

Strona 108

FIGURE A.22 Bottom view drawing of the rack equipped with the pullout stabilizer (standard type only) Bottom view drawing of connected 19-inch racks (

Strona 109

FIGURE A.23 Bottom view drawing of connected 19-inch racks (standard) Bottom view drawing of connected 19-inch racks (slim) FIGURE A.24 Bottom view