viii SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009▼ Remove the Top Cover 67Servicing Hard Drives 69Hard Drive Servicing Overview

Strona 3 - Service Manual

74 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – SPARC Enterprise T5120 servers might have up to seven blank panelscoverin

Strona 4

Servicing Hard Drives 754. At the Solaris prompt, type the cfgadm -al command. This will list all drivesin the device tree, including drives that are

Strona 5

76 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20097. At the Solaris prompt, type the cfgadm -al command to list all drives in thed

Strona 6

Servicing Hard Drives 77Four-Drive Capable BackplaneConfiguration ReferenceThe following table shows the physical hard drive locations in a four-drive

Strona 7 - Contents

78 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Eight-Drive Capable BackplaneConfiguration ReferenceThe first table below identi

Strona 8

Servicing Hard Drives 79Sixteen-Drive Capable BackplaneConfiguration ReferenceThe first table below identifies the hard drive slot numbering in a sixt

Strona 9

80 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “Install a Hard Drive” on page 73 “Remove a Hard Drive” on

Strona 10

81Servicing Motherboard ComponentsThese topics explain how to replace the motherboard and its components in theSPARC Enterprise T5120 and SPARC Enterp

Strona 11

82 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Memory Fault Handling OverviewA variety of features play a role in how the memor

Strona 12

Servicing Motherboard Components 83▼ Identify Faulty FB-DIMMs Using the showfaulty CommandThe ILOM show faulty command displays current system faults,

Strona 13

Contents ix▼ Remove a PCIe/XAUI Riser 102▼ Install a PCIe/XAUI Riser 104▼ Remove a PCIe or XAUI Card 106▼ Install a PCIe or XAUI Card 107PCIe/XAUI Car

Strona 14

84 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – The FB-DIMM Fault Locator button is near the left edge of the motherboard

Strona 15 - Before You Read This Document

Servicing Motherboard Components 85Related Information “Identify Faulty FB-DIMMs Using the show faulty Command” on page 83▼ Remove FB-DIMMsBefore beg

Strona 16

86 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing FB-DIMMs6. Press the Fault Locator button on the motherboard to

Strona 17 - Related Documentation

Servicing Motherboard Components 879. Place the FB-DIMM on an antistatic mat.10. Repeat Step 7 through Step 9 for any other FB-DIMMs you intend to rem

Strona 18 - Title Description Manual Code

88 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing FB-DIMMs7. Align the FB-DIMM notch with the key in the connec

Strona 19 - Text Conventions

Servicing Motherboard Components 89Note – As soon as the power cords are connected, standby power is applied.Depending on how the firmware is configur

Strona 20 - Prompt Notations

90 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – The server takes about one minute to power off. Use the show /HOSTcommand

Strona 21 - Notes on Safety

Servicing Motherboard Components 916. Run the show faulty command.If the show faulty command reports a fault with a UUID go on to Step 7.Ifshow faulty

Strona 22 - Task Warning

92 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Caution – You must disconnect the power cables from the system before performing

Strona 23 - Preface xxi

Servicing Motherboard Components 93Note – If the FB-DIMM does not easily seat into the connector, it may not have thecorrect orientation. If the orien

Strona 24 - Product Handling

x SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Servicing Power Supplies 129Power Supplies Overview 129Power Supply Status LEDs 1

Strona 25 - Alert Label

94 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – The server takes about one minute to power off. The ILOM console does not

Strona 26

Servicing Motherboard Components 95FB-DIMM Configuration GuidelinesUse the guidelines described in this topic when installing, upgrading, or replacing

Strona 27 - Identifying Server Components

96 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FB-DIMM Configuration ReferenceThe following figure illustrates the physical arr

Strona 28

Servicing Motherboard Components 97FIGURE: FB-DIMM Slot Layout on the MotherboardFigure Legend1 Branch 3 FB-DIMM slots2 Branch 2 FB-DIMM slots3 Branch

Strona 29

98 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009The following table maps FB-DIMM locations with FB-DIMM FRU names. The FRUname i

Strona 30

Servicing Motherboard Components 99FIGURE: Slot Use Map for Quantities of 4, 8, and 16 FB-DIMMsFigure Legend1 4 FB-DIMM configuration2 8 FB-DIMM confi

Strona 31

100 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “Identify Faulty FB-DIMMs Using the show faulty Command” o

Strona 32 - 3 PowerOKLED 7 Overtemp LED

Servicing Motherboard Components 1013. (SPARC Enterprise T5120 server; 8 drive-capable) Disconnect and stow the harddrive data cable.a. Route the hard

Strona 33

102 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Servicing PCIe/XAUI RisersThese topics explain how to service the riser units t

Strona 34

Servicing Motherboard Components 1032. Disconnect all power cables.See “Disconnect Power Cords From the Server” on page 62.3. Attach an antistatic wri

Strona 35

Contents xiServicing Power Distribution Boards 160Power Distribution Board Overview 160▼ Remove the Power Distribution Board 161▼ Install the Power Di

Strona 36

104 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing the PCIe/XAUI Riser (SPARC Enterprise T5220 Server)8. Loosen t

Strona 37

Servicing Motherboard Components 105FIGURE: Installing the PCIe/XAUI Riser (SPARC Enterprise T5120)FIGURE: Installing the PCIe/XAUI Riser (SPARC Enter

Strona 38

106 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20095. Engage the two captive Phillips screws on both sides of the removable PCI cr

Strona 39

Servicing Motherboard Components 107 SPARC Enterprise T5220: PCIe filler panels are located on the riser boardassembly. Press the filler panel into t

Strona 40 - Network Management Port

108 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing a PCIe Card (SPARC Enterprise T5120) SPARC Enterprise T5220

Strona 41 - Detecting and Managing Faults

Servicing Motherboard Components 109FIGURE: Installing a PCIe Card (SPARC Enterprise T5220)6. Insert the PCIe/XAUI card into the correct slot on the r

Strona 42 - Service Processor Interfaces

110 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 200911. Connect the power supplies.See “Connect Power Cords to the Server” on page

Strona 43

Servicing Motherboard Components 111PCIe and XAUI Card Reference for SPARCEnterprise T5220 ServersThe following table shows the physical PCIe/XAUI slo

Strona 44 - Diagnostics Flowchart

112 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “Remove a PCIe or XAUI Card” on page 106 “Install a PCIe

Strona 45

Servicing Motherboard Components 113FIGURE: Battery Location (SPARC Enterprise T5120 Server Shown)Related Information “Remove a Battery” on page 113

Strona 46

xii SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009HDD Data Cable Routing for SAS RAID Controller Cards in Eight-DiskCapable SPARC

Strona 47 - LED Overview

114 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009▼ Install a Battery1. Unpack the replacement battery.2. Press the new battery i

Strona 48 - Detecting Faults With ILOM

Servicing Motherboard Components 115 Replacing a faulty SCC module -- When replacing a faulty SCC module, youmust obtain the host ID, MAC addresses,

Strona 49 - ILOM Troubleshooting Overview

116 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – The server will not function correctly without the SCC module installed.

Strona 50

Servicing Motherboard Components 1179. If the previous SCC module had modified ILOM configuration variables andyou recorded them, configure the new SC

Strona 51 - Processor

118 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – The firmware configuration variable settings are not stored in the SCCmo

Strona 52 - Service-Related Commands

Servicing Motherboard Components 119Note – Make note of the location of expansion cards in PCIe/XAUI risers 0 and 1.10. Disconnect the motherboard-to-

Strona 53

120 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing the Motherboard Assembly (SPARC Enterprise T5120 Server Shown)

Strona 54

Servicing Motherboard Components 121FIGURE: Installing the Motherboard Assembly (SPARC Enterprise T5120 Server)3. Using the green handle and the back

Strona 55

122 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20096. If you are installing a new motherboard, install the following components:a.

Strona 56

123Servicing Fan ModulesThese topics explain how to service faulty fan modules. “Fan Module Overview” on page 123 “Remove a Fan Module” on page 125

Strona 57 - ▼ Clear FRU Faults Manually

xiiiPrefaceThis manual provides detailed procedures that describe the removal and replacementof replaceable parts in the SPARC Enterprise™ T5120 and T

Strona 58 - ▼ Create an ALOM CMT Shell

124 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Fan Module Configurations for SPARC EnterpriseT5120 Servers (4- and 8-Disk Capa

Strona 59

Servicing Fan Modules 125Fan Module Status LEDsEach fan module contains a pair of LEDs, which are visible when you open the fancompartment access door

Strona 60 - Detecting Faults With POST

126 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20091. Extend the server to the maintenance position.See “Extend the Server to the

Strona 61 - Managing POST Operations

Servicing Fan Modules 127FIGURE: Removing a Fan ModuleRelated Information “Extend the Server to the Maintenance Position” on page 63▼ Install a Fan M

Strona 62 - Parameter Values Description

128 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing a Fan Module2. Apply firm pressure to fully seat the fan mod

Strona 63 - Examples of POST Management

129Servicing Power SuppliesThe topics explain how to remove and replace power supply modules. “Power Supplies Overview” on page 129 “Remove a Power

Strona 64

130 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Power Supply LEDs (SPARC Enterprise T5120 Server Shown)The following ta

Strona 65 - ▼ Run POST in Maximum Mode

Servicing Power Supplies 131 “Servicing Power Supply Backplanes (SPARC Enterprise T5220 Servers)” onpage 167 “Remove a Power Supply” on page 131 “I

Strona 66

132 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Cable management Arm Release Mechanism4. Based on the model of your ser

Strona 67 - ▼ Clear POST-Detected Faults

Servicing Power Supplies 133FIGURE: Power Supply Release Handle (SPARC Enterprise T5120 Servers)FIGURE: Power Supply Release Handle (SPARC Enterprise

Strona 68 - POST Output Quick Reference

xiv SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Structure and Contents of This ManualThis manual is organized as described belo

Strona 69

134 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009▼ Install a Power Supply1. Align the replacement power supply with the empty po

Strona 70 - Solaris PSH Feature Overview

Servicing Power Supplies 135FIGURE: Installing a Power Supply (SPARC Enterprise T5220 Server)3. Based on the model of your server (AC or DC), apply po

Strona 71

136 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20097. At the ALOM CMT sc> prompt, type the showenvironment command toverify the

Strona 72

137Servicing Boards and ComponentsThese topics explain how to service field-replaceable units (FRUs) in SPARCEnterprise T5120 and T5220 servers. “Imp

Strona 73 - ▼ Clear PSH-Detected Faults

138 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – Fan modules are the only chassis components that may be removed orinstal

Strona 74 - Viewing Solaris OS Messages

Servicing Boards and Components 139Related Information “Remove the Hard Drive Backplane” on page 152DVD/USB Module OverviewThe DVD ROM drive and fron

Strona 75 - System Recovery Commands

140 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20092. Unplug the power cords.See “Disconnect Power Cords From the Server” on page

Strona 76 - ▼ Display System Components

Servicing Boards and Components 141FIGURE: Removing the DVD/USB Module (illustrates removal from a SPARC EnterpriseT5120 server)6. Slide the DVD/USB m

Strona 77 - ▼ Disable System Components

142 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing the DVD/USB Module (Illustrates installing in a SPARC Enterp

Strona 78 - ▼ Enable System Components

Servicing Boards and Components 143Servicing Fan Power BoardsThese topics explain how to remove and install fan power boards. “Fan Power Board Overvi

Strona 79 - ▼ Run the SunVTS Software

Preface xvRelated DocumentationThe latest versions of all the SPARC Enterprise Series manuals are available at thefollowing Web sites:Global Site(http

Strona 80 - SunVTS Browser Interface

144 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20092. Disconnect the power cables.See “Disconnect Power Cords From the Server” on

Strona 81

Servicing Boards and Components 145Related Information “Install the Fan Power Board” on page 145▼ Install the Fan Power Board1. Lower the board into

Strona 82

146 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “Remove the Fan Power Board” on page 143Servicing the Hard

Strona 83 - General Safety Information

Servicing Boards and Components 1472. Disconnect all external cables.3. Remove the server from the rack. Place the server on a hard, flat surface.See

Strona 84 - Antistatic Wrist Strap Use

148 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing a Hard Drive Cage (Illustrating Removal From a SPARC Enterpris

Strona 85 - Essential Tools

Servicing Boards and Components 149 “Remove the Hard Drive Backplane” on page 152▼ Install the Hard Drive CageBefore performing any installation step

Strona 86 - Command)

150 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing a Hard Drive Cage (Illustrating Installation in a SPARC Ente

Strona 87

Servicing Boards and Components 1513. (SPARC Enterprise T5120 server, 8 disk-capable) Remove fan FM1.4. Slide the hard drive cage back until the hard

Strona 88

152 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 200914. Power on the system.See “Power On the Server Using the poweron Command” on

Strona 89

Servicing Boards and Components 153 Four screws secure the backplane in the SPARC Enterprise T5220 server. See thesecond figure below.FIGURE: Removin

Strona 90 - Slide Release Latches

xvi SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009SPARC Enterprise T5120 andT5220 Servers Installation GuideDetailed rackmounting

Strona 91

154 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing a Hard Drive Backplane (Illustrating removal from a SPARCEnter

Strona 92 - Accessing Internal Components

Servicing Boards and Components 155FIGURE: Installing a Hard Drive Backplane in a SPARC Enterprise T5120 Server

Strona 93 - ▼ Remove the Top Cover

156 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing a Hard Drive Backplane in a SPARC Enterprise T5220 Server3.

Strona 94

Servicing Boards and Components 157Front Control Panel Light Pipe AssembliesOverviewThe front control panel light pipe assemblies are mounted on each

Strona 95 - Servicing Hard Drives

158 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing the Front Control Panel Light Pipe Assembly From a SPARCEnterp

Strona 96 - Hard Drive LEDs

Servicing Boards and Components 159FIGURE: Installing a Front Control Panel Light Pipe Assembly in a SPARC EnterpriseT5220 Server3. Secure the light p

Strona 97 - ▼ Remove a Hard Drive

160 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Servicing Power Distribution BoardsThe following topics explain how to remove a

Strona 98

Servicing Boards and Components 161▼ Remove the Power Distribution Board1. Note the chassis serial number and part number.The chassis serial number an

Strona 99 - ▼ Install a Hard Drive

162 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing a Power Distribution Board From a SPARC Enterprise T5220 Serve

Strona 100

Servicing Boards and Components 163FIGURE: Removing the Power Distribution Board From a SPARC Enterprise T5120 Server8. Grasp the bus bar and pull the

Strona 101 - Servicing Hard Drives 75

Preface xviiNote – Product Notes are available on the website only. Please check for the recentupdate on your product.UNIX CommandsThis document might

Strona 102 - Related Information

164 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing a Power Distribution Board in a SPARC Enterprise T5120 Serve

Strona 103 - Configuration Reference

Servicing Boards and Components 165FIGURE: Installing a Power Distribution Board in a SPARC Enterprise T5220 Server5. (SPARC Enterprise T5220 server)

Strona 104 - Eight-Drive Capable Backplane

166 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing a Power Supply in a SPARC Enterprise T5120 Server8. Install

Strona 105

Servicing Boards and Components 167Caution – When performing the following steps, use special care to enter the correctnumbers. Once the power distrib

Strona 106

168 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Power Supply Backplane OverviewThe power supply backplane carries 12V power fro

Strona 107 - Servicing FB-DIMMs

Servicing Boards and Components 169FIGURE: Removing a Power Supply From a SPARC Enterprise T5220 Server3. Remove the power distribution board.See “Rem

Strona 108

170 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “Install the Power Supply Backplane” on page 170▼ Install

Strona 109 - Fault Locator Button

Servicing Boards and Components 171FIGURE: Installing a Power Supply (Illustrating Installation of a Power Supply in aSPARC Enterprise T5220 Server)5.

Strona 110

172 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Paddle Card OverviewThe paddle card serves as the interconnect between the powe

Strona 111 - ▼ Remove FB-DIMMs

Servicing Boards and Components 1736. Tilt the paddle card away from the side of the chassis and lift the paddle cardup and out of the system.7. Place

Strona 113

xviii SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Prompt NotationsThe following prompt notations are used in this manual.Conven

Strona 114 - Installing FB-DIMMs

174 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009

Strona 115 - FB-DIMMs

175Returning the Server to OperationThese topics explain how to return SPARC Enterprise T5120 and T5220 servers tooperation after you have performed s

Strona 116

176 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Installing the Top CoverNote – If an emergency shutdown occurred when t

Strona 117 - Additional FB-DIMMs

Returning the Server to Operation 177FIGURE: Returning the Server to the Rack2. Slide the server into the rack until the brackets lock into place.The

Strona 118

178 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Release Tabs on the Rail2. While pushing on the release tabs, slowly pu

Strona 119 - Stopping /SYS

Returning the Server to Operation 179Note – As soon as the power cords are connected, standby power is applied.Depending on how the firmware is config

Strona 120

180 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009▼ Power On the Server Using the FrontPanel Power Button● Use a pointed object,

Strona 121

181Identifying FRUs in SPARCEnterprise T5120 ServersThese topics identify and illustrate Field Replaceable Units (FRUs) contained inSPARC Enterprise T

Strona 122

182 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Motherboard Components in T5120ServersFIGURE: Motherboard Components (SPARC Ent

Strona 123 - Figure Legend

Identifying FRUs in SPARC Enterprise T5120 Servers 183The following table identifies the components located on the motherboard and pointsto instructio

Strona 124 - FB-DIMM Installation Map

Preface xixCaution – This indicates that hazardous voltages are present. To reduce the risk ofelectric shock and danger to personal health, follow the

Strona 125 - 3 16 FB-DIMM configuration

184 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009I/O Components in SPARC EnterpriseT5120 ServersFIGURE: I/O Components (SPARC En

Strona 126 - Servicing the Air Duct

Identifying FRUs in SPARC Enterprise T5120 Servers 185The following table identifies the I/O components in the server and points toinstructions for se

Strona 127 - ▼ Install the Air Duct

186 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Power Distribution/Fan ModuleComponents in SPARC Enterprise T5120ServersFIGURE:

Strona 128 - Servicing PCIe/XAUI Risers

Identifying FRUs in SPARC Enterprise T5120 Servers 187The following table identifies the power distribution and fan module components inthe server and

Strona 129

188 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Internal Cables for Onboard SASController Cards in SPARC EnterpriseT5120 Server

Strona 130 - ▼ Install a PCIe/XAUI Riser

Identifying FRUs in SPARC Enterprise T5120 Servers 189FIGURE: HDD Cable from Onboard SAS to HDD Backplane (4-Disk Capable SPARCEnterprise T5120 Server

Strona 131

190 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Internal Cables for the Onboard SAS Controller Card (Eight-Disk Capable

Strona 132 - ▼ Remove a PCIe or XAUI Card

Identifying FRUs in SPARC Enterprise T5120 Servers 191HDD Data Cable Routing for SAS RAIDController Cards in Four-Disk CapableSPARC Enterprise T5120 S

Strona 133 - ▼ Install a PCIe or XAUI Card

192 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Hard Drive Data Cable Routing for SAS RAID Controller Card in Four-Disk

Strona 134

Identifying FRUs in SPARC Enterprise T5120 Servers 193HDD Data Cable Routing for SAS RAIDController Cards in Eight-Disk CapableSPARC Enterprise T5120

Strona 135

xx SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Caution – This indicates that hazardous voltages are present. To reduce the risk

Strona 136

194 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Hard Drive Data Cable Routing for SAS RAID Controller Card in Eight-Dis

Strona 137 - Enterprise T5220 Servers

195Identifying FRUs in SPARCEnterprise T5220 ServersThese topics identify and illustrate Field Replaceable Units (FRUs) contained inSPARC Enterprise T

Strona 138 - Servicing the Battery

196 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Motherboard Components in T5220ServersFIGURE: Motherboard Components in SPARC E

Strona 139 - ▼ Remove a Battery

Identifying FRUs in SPARC Enterprise T5220 Servers 197The following table identifies the components located on the motherboard and pointsto instructio

Strona 140 - Servicing the SCC Module

198 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009I/O Components in SPARC EnterpriseT5220 ServersFIGURE: I/O Components (SPARC En

Strona 141 - ▼ Remove a Faulty SCC Module

Identifying FRUs in SPARC Enterprise T5220 Servers 199The following table identifies the I/O components in the server and points toinstructions for se

Strona 142 - ▼ Install a New SCC Module

200 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Power Distribution/Fan ModuleComponents in SPARC Enterprise T5220ServersFIGURE:

Strona 143

Identifying FRUs in SPARC Enterprise T5220 Servers 201The following table identifies the power distribution and fan module components inthe server and

Strona 144

202 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Internal Cables for Onboard SASController Cards in SPARC EnterpriseT5220 Server

Strona 145 - ■ SCC Module

Identifying FRUs in SPARC Enterprise T5220 Servers 203FIGURE: Internal Cables for Onboard SAS Controller Cards (Eight-Disk Capable SPARC Enterprise T5

Strona 146

Preface xxiCaution – This indicates that surfaces are hot and might cause personal injury iftouched. Avoid contact.Task WarningMaintenance Extremely h

Strona 147

204 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Internal Cables for the Onboard SAS Controller Card (Eight-Disk Capable

Strona 148

Identifying FRUs in SPARC Enterprise T5220 Servers 205FIGURE: Internal Cables for Onboard SAS Controller Cards (Sixteen-Disk Capable SPARCEnterprise T

Strona 149 - Servicing Fan Modules

206 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009HDD Data Cable Routing for SAS RAIDController Cards in SPARC EnterpriseT5220 Se

Strona 150

Identifying FRUs in SPARC Enterprise T5220 Servers 207FIGURE: HDD Data Cable Routing for SAS RAID Controller Cards in Eight- orSixteen-Disk Capable SP

Strona 151 - ▼ Remove a Fan Module

208 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009

Strona 152

209IndexAabout, 16AC Present (power supply LED), 19, 135airflow, blocked, 20antistatic wrist strap, 58ASR blacklist, 50asrkeys (system components), 51B

Strona 153 - ▼ Install a Fan Module

210 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009fan power boardFRU name, 187, 201Fault (fan module LED), 128Fault (hard drive L

Strona 154

Index 211power supplyabout, 129AC Present LED, 19, 135Fault LED, 21, 131FRU name, 136, 187, 201Power Supply Fault (system LED)interpreting to diagnose

Strona 155 - Servicing Power Supplies

212 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009removing, 67topic guidelines, 1, 15, 57, 69, 81, 123, 129, 137, 175,181, 195tro

Strona 157 - ▼ Remove a Power Supply

xxii SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Product HandlingMaintenanceWarning – Certain tasks in this manual should only

Strona 159 - Servicing Power Supplies 133

Preface xxiiiAlert LabelThe following is a label attached to this product: Never peel off the label. The following label provides information to the

Strona 160 - ▼ Install a Power Supply

xxiv SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Fujitsu Welcomes Your CommentsIf you have any comments or requests regarding t

Strona 161 - Servicing Power Supplies 135

1Identifying Server ComponentsThese topics identify key components of the SPARC Enterprise T5120 and T5220servers, including major boards and internal

Strona 162 - /SYS/PS0

2 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Infrastructure Boards in SPARCEnterprise T5120 ServersSPARC Enterprise T5120 serv

Strona 163 - Important Safety Instructions

Identifying Server Components 3 “Identifying FRUs in SPARC Enterprise T5120 Servers” on page 181 “Identifying FRUs in SPARC Enterprise T5220 Servers

Strona 164 - Servicing DVD/USB Modules

SPARC EnterpriseTMT5120 and T5220 ServersService ManualPart No. 875-4194-13July 2009, Revision AManual Code C120-E463-04EN

Strona 165 - ▼ Remove the DVD/USB Module

4 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “Infrastructure Boards in SPARC Enterprise T5120 Servers” on

Strona 166

Identifying Server Components 5Internal System Cables for SPARCEnterprise T5220 ServersThe following table identifies the internal system cables used

Strona 167 - ▼ Install the DVD/USB Module

6 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Front Panel Controls and Indicators on SPARC Enterprise T5120 ServersFigu

Strona 168

Identifying Server Components 7The following table provides descriptions of these controls and indicators.TABLE: Front Panel Controls and Indicators (

Strona 169 - Servicing Fan Power Boards

8 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “LED Overview” on page 21Rear Panel Components and Indicator

Strona 170 - T5120 server)

Identifying Server Components 9The following table provides descriptions of the LEDs located on the rear panel.Related Information “LED Overview” on

Strona 171 - ▼ Install the Fan Power Board

10 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Front Panel Controls and Indicators on SPARC Enterprise T5220 ServersFig

Strona 172 - Servicing the Hard Drive Cage

Identifying Server Components 11The following table provides descriptions of these controls and indicators.TABLE: Front Panel Controls and Indicators

Strona 173

12 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Related Information “LED Overview” on page 21Rear Panel Components and Indicato

Strona 174

Identifying Server Components 13The following table provides descriptions of the LEDs located on the rear panel.Related Information “LED Overview” on

Strona 175 - ▼ Install the Hard Drive Cage

PleaseRecycleCopyright © 2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.FUJITSU LIMITED p

Strona 176 - T5220 Server)

14 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Status LEDs for Ethernet Ports andNetwork Management PortThe following table des

Strona 177

15Detecting and Managing FaultsThese topics explain how to use various diagnostic tools to monitor server status andtroubleshoot faults in the server.

Strona 178 - Hard Drive Backplane Overview

16 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009 Power-on self-test (POST) – POST performs diagnostics on system componentswhen

Strona 179 - Enterprise T5120 server)

Detecting and Managing Faults 17Multiple service processor accounts can be active concurrently. A user can issueILOM shell commands while logged in un

Strona 180

18 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Diagnostics Flowchart

Strona 181

Detecting and Managing Faults 19The following table provides brief descriptions of the troubleshooting actions shownin the flowchart. It also provides

Strona 182 - Assemblies

20 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Check if the fault isenvironmental.(Flowchart item 6)Determine if the fault is a

Strona 183 - Overview

Detecting and Managing Faults 21LED OverviewThe server provides the following groups of LEDs: Front panel system LEDs Rear panel system LEDs Hard d

Strona 184

22 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Detecting Faults With ILOMThese topics explain how to use ILOM, the service proc

Strona 185

Detecting and Managing Faults 23ILOM Troubleshooting OverviewILOM enables you to remotely run diagnostics such as power-on self-test (POST),that would

Strona 186

Copyright © 2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, Etats-Unis. Tous droits réservés.Entrée et revue tecnical

Strona 187

24 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – No ILOM command is needed to manually repair an environmental fault.The s

Strona 188

Detecting and Managing Faults 25How to Switch From the System Console to the ServiceProcessorThe following example shows the character sequence (hash-

Strona 189

26 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Service-Related ILOM Command SummaryThe following table describes the ILOM shell

Strona 190

Detecting and Managing Faults 27set /HOST/bootmode property=value[where property is state, config,or script]bootmode [normal] [reset_nvram][config=con

Strona 191

28 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009set /SYS/LOCATE value=value[Fast_blink | Off]setlocator value[on | off]Turns the

Strona 192

Detecting and Managing Faults 29Related Information “Managing Components With Automatic System Recovery Commands” onpage 50Faults Displayed by show f

Strona 193

30 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Example of show faulty Output When No Fault isPresentExample of show faulty Outp

Strona 194

Detecting and Managing Faults 31PSH TechnologyRelated Information “Clear FRU Faults Manually” on page 31 “Display FRU Information With the show Comm

Strona 195

32 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009▼ Display FRU Information With the showCommand● At the -> prompt, enter the s

Strona 196

Detecting and Managing Faults 33The service processor sends email alerts to all ALOM CMT users that are logged in.It also enters the event in the ILOM

Strona 198 - ▼ Remove the Paddle Card

34 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20093. Log out of the root account after you have finished creating the new account.

Strona 199 - ▼ Install the Paddle Card

Detecting and Managing Faults 35POST OverviewPower-on self-test (POST) is a group of PROM-based tests that run when the server ispowered on or when it

Strona 200

36 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – The value of keyswitch_state must be normal when individual POSTparameter

Strona 201 - ▼ Install the Top Cover

Detecting and Managing Faults 37FIGURE: Flowchart of ILOM Properties Used to Manage POST OperationsExamples of POST ManagementThis topic shows example

Strona 202

38 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – When you change individual POST parameter values, thekeyswitch_state valu

Strona 203 - Position

Detecting and Managing Faults 39▼ Run POST in Maximum ModePOST can be helpful when used as a first-stage diagnostic tool. When a fault’ssymptoms are u

Strona 204

40 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20094. If POST detects a faulty device, information about the device will be passed

Strona 205

Detecting and Managing Faults 41Note – The system can boot and run using memory that was not disabled.Related Information “Clear POST-Detected Faults

Strona 206 - Panel Power Button

42 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20092. Clear the fault by setting the FRU’s component_state property to Enabled.This

Strona 207 - Enterprise T5120 Servers

Detecting and Managing Faults 43The following example. POST reports a memory error at FB-DIMM location/SYS/MB/CMP0/BR1/CH0/D0. The error was detected

Strona 208

vContentsPreface xiiiIdentifying Server Components 1Infrastructure Boards in SPARC Enterprise T5120 Servers 2Infrastructure Boards in SPARC Enterprise

Strona 209

44 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Solaris PSH Feature OverviewThe Solaris OS uses the Fault Manager daemon, fmd(1M

Strona 210 - T5120 Servers

Detecting and Managing Faults 45PSH-detected faults also cause the Service Required LED to be turned on.Use the ILOM show faulty command to view summa

Strona 211

46 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20091. Check the event log using the fmdump command with -v for verbose output.In th

Strona 212 - Power Distribution/Fan Module

Detecting and Managing Faults 473. Follow the suggested actions to repair the fault.▼ Clear PSH-Detected FaultsWhen the Solaris PSH facility detects f

Strona 213

48 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20093. Use the clear_fault_action property of the FRU to clear the fault from theser

Strona 214

Detecting and Managing Faults 49The /var/adm directory contains several message files. The most recent messagesare in the /var/adm/messages file. Afte

Strona 215 - Enterprise T5120 Server)

50 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009The database that contains the list of disabled components is referred to as the

Strona 216

Detecting and Managing Faults 51● At the -> prompt, enter the show components command.In the following example, PCIE3 is shown as disabled.Related

Strona 217

52 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Note – In the ILOM shell there is no notification when the system is actuallypow

Strona 218 - Servers

Detecting and Managing Faults 53Detecting Faults Using SunVTS SoftwareThis topic explains in general terms how to use SunVTS software to exercise syst

Strona 219

vi SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009How to Switch From the System Console to the Service Processor 25How to Switch F

Strona 220

54 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: SunVTS Browser Interface4. (Optional) Select the test category you want

Strona 221

Detecting and Managing Faults 556. Click the Start button to start the test process. Status and error messages appearin the test messages area located

Strona 222

56 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009

Strona 223

57Preparing to Service the SystemThese topics describe how to prepare the SPARC Enterprise T5120 and T5220 serversfor servicing. “General Safety Info

Strona 224 - T5220 Servers

58 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Caution – There is a risk of personal injury or equipment damage. To avoidperson

Strona 225

Preparing to Service the System 59Antistatic MatPlace ESD-sensitive components such as motherboards, memory, and other PCBs onan antistatic mat.Essent

Strona 226

60 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009Removing Power From the SystemThese topics describe different methods for removi

Strona 227

Preparing to Service the System 61Note – Additional information about powering off the server is located in the SPARCEnterprise T5120 and T5220 Server

Strona 228

62 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009▼ Power Off the Server (Power Button - Graceful)● Press and release the Power bu

Strona 229 - Servers)

Preparing to Service the System 63▼ Extend the Server to the Maintenance PositionThe following components can be serviced with the server in the maint

Strona 230

Contents viiViewing Solaris OS Messages 48▼ Check the Message Buffer 49▼ View the System Message Log Files 49Managing Components With Automatic System

Strona 231 - Enterprise T5220 Servers)

64 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Slide Release Latches4. While squeezing the slide release latches, slowl

Strona 232

Preparing to Service the System 651. Disconnect all the cables and power cords from the server.2. Extend the server to the maintenance position.See “P

Strona 233

66 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20094. From the front of the server, pull the release tabs forward and pull the serv

Strona 234

Preparing to Service the System 67▼ Perform Electrostatic Discharge PreventionMeasuresMany components housed within the chassis can be damaged by elec

Strona 235

68 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009FIGURE: Removing the Top Cover3. Remove the top cover.Lift up and remove the cov

Strona 236

69Servicing Hard DrivesThese topics explain how to remove and install hard drives in SPARC EnterpriseT5120 and T5220 servers. “Hard Drive Servicing O

Strona 237 - Index 211

70 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 2009If either of these conditions exist, you must power off the server before replac

Strona 238

Servicing Hard Drives 71The following table explains how to interpret the hard drive status LEDs.Note – The front and rear panel Service Required LEDs

Strona 239

72 SPARC Enterprise T5120 and T5220 Servers Service Manual • July 20091. At the Solaris prompt, type the cfgadm -al command. This will list all drives

Strona 240

Servicing Hard Drives 73FIGURE: Locating the Hard Drive Release Button and LatchCaution – The latch is not an ejector. Do not bend the latch too far t