5-6 C141-E205
Figure 5.3 CN2 setting terminal (on NP models only)
5.3.1 SCSI ID setting
Table 5.1 shows the SCSI ID setting. For the terminal location and allocation of NC model, see
Figure 4.13 and Table B.1. For NP model, see Figure 5.2 and 5.3.
IMPORTANT
When the SCSI ID is set using the external operator panel connector
CN1 of NP model, all pins listed in Table 5.1 should be open. If any
of pins are shorted, unexpected SCSI ID is set.
24 22 20 18 16 14 12 10 8 6
4 2
23 21 19 17 15 13 11 9 7 5 3 1
Terminator power supply: Supply
(LED signal)
(IDD Reset signal)
N.C.
Force Single Ended: LVD mode
Force Narrow: 16-bit SCSI
Motor start mode
Write protect: enabled
SCSI ID #15