152 ServerView Event Manager
Trap overview
tapeAlertTrap32 32 The tape drive has a
problem with the host
interface:
1. Check the cables and
cable connections.
2. Restart the operation.
minor
tapeAlertTrap33 33 The operation has failed:
1. Eject the tape or
magazine.
2. Insert the tape or
magazine again.
3. Restart the operation.
critical
tapeAlertTrap34 34 The firmware download has
failed because you have
tried to use the incorrect
firmware for this tape drive.
Obtain the correct firmware
and try again.
minor
tapeAlertTrap35 35 Environmental conditions
inside the tape drive are
exceeding the humidity
specifications.
minor
tapeAlertTrap36 36 Environmental conditions
inside the tape drive are
exceeding the temperature
specifications.
minor
tapeAlertTrap37 37 The voltage supply to the
tape drive exceeds
specifications.
minor
tapeAlertTrap38 38 A hardware failure of the
tape drive is predicted. Call
the tape drive supplier
helpline.
critical
Trap name ID Meaning Error class
Table 45: Tape traps
Przeglądanie stron 151
1 2 ... 147 148 149 150 151 152 153 154 155 156 157 ... 173 174