Fujitsu ServerView V6.00 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Komputery Fujitsu ServerView V6.00. FUJITSU ServerView V6.00 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 174
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - ServerView Event Manager

User Guide - EnglishFujitsu Software ServerView Suite ServerView Event Manager ServerView Operations Manager V6.20Edition June 2013

Strona 2 - Copyright and Trademarks

10 ServerView Event ManagerDocumentation for ServerView SuiteAccess to the link collectionYou can reach the link collection of the ServerView Suite

Strona 3 - Contents

100 ServerView Event ManagerTrap overview5.3.4 Cluster traps (NTCluster.mib)MIB-OID: 1.3.6.1.4.1.231This section lists cluster traps in alphabetical

Strona 4

ServerView Event Manager 101Trap overviewsniWpChangeNetworkDeleted910 A network was deleted from the cluster.criticalsniWpChangeNetworkProperty913 Th

Strona 5

102 ServerView Event ManagerTrap overviewsniWpChangeUnknown801 The cluster API has returned a note type that does not have an associated trap defini

Strona 6 - ServerView Event Manager

ServerView Event Manager 103Trap overview5.3.5 DPT traps (dptscsi.mib)MIB-OID: 1.3.6.1.4.1.1597This section lists DPT traps in alphabetical order.Tra

Strona 7 - 1 Introduction

104 ServerView Event ManagerTrap overviewdptDevStatusChangedTrap9 Status of the SCSI device changed.informationaldptHbaCorrectedHardRAMErrorTrap4 Th

Strona 8

ServerView Event Manager 105Trap overview5.3.6 DuplexDataManager traps (Ddm.mib)MIB-OID: 1.3.6.1.4.1.231.2.10.2This section lists DuplexDataManager t

Strona 9 - ServerView Event Manager 9

106 ServerView Event ManagerTrap overviewFscDdmReservationConflict1407 A reservation conflict has been detected. From now on an entire DuplexWrite g

Strona 10 - ServerView Event Manager

ServerView Event Manager 107Trap overviewFscDdmNameChanged 1414 After the driver has changed the name of a DuplexWrite group.informationalFscDdmPathF

Strona 11 - 1.4 Notational conventions

108 ServerView Event ManagerTrap overviewFscDdmDdmCluster 1424 After the DuplexDataManager service has detected a cluster configuration change.infor

Strona 12 - Notational conventions

ServerView Event Manager 109Trap overview5.3.7 DuplexWrite traps (DW.mib)MIB-OID: 1.3.6.1.4.1.231.2.10.2This section lists DuplexWrite traps in alpha

Strona 13 - 2Event Manager

ServerView Event Manager 11Notational conventions1.4 Notational conventionsThe following notational conventions are used in this manual:References to

Strona 14 - 2.1 First-time startup

110 ServerView Event ManagerTrap overviewsieDWPieceFailed 1311 The driver has detected an error on one of the disks of a DuplexWrite group.criticals

Strona 15 - ServerView Event Manager 15

ServerView Event Manager 111Trap overview5.3.8 Hard disk (S.M.A.R.T.) traps (Hd.mib)This section lists hard disk traps in alphabetical order.MIB-OID:

Strona 16 - 2.3 Icons

112 ServerView Event ManagerTrap overview5.3.9 Generic trapsThis section lists generic traps in alphabetical order.Trap name ID Meaning Error class

Strona 17 - Yellow: Forwarding completed

ServerView Event Manager 113Trap overview5.3.10 MultiPath traps (mp.mib)MIB-OID: 1.3.6.1.4.1.231.2.10.2This section lists MultiPath traps in alphabet

Strona 18 - 18 ServerView Event Manager

114 ServerView Event ManagerTrap overview5.3.11 Mylex traps (Mylex.mib)MIB-OID: 1.3.6.1.4.1.231.2.10.2This section lists Mylex traps in alphabetical

Strona 19 - 3 Alarm Monitor

ServerView Event Manager 115Trap overviewmylexLogicalDriveOffline 214 Logical drive is offline.critical mylexLogicalDriveOnline 216 Logical drive is

Strona 20

116 ServerView Event ManagerTrap overviewmylexPhysicalDevicePrefailure255 Prefailure alert from physical device.major mylexPhysicalDeviceRemoved258

Strona 21 - ServerView Event Manager 21

ServerView Event Manager 117Trap overviewmylexRebuildNewDeviceFailed206 Rebuild finished; new device failed.major mylexRebuildNewDeviceFailed2227 Reb

Strona 22

118 ServerView Event ManagerTrap overview5.3.12 PCI HotPlug traps (pcihotplug.mib)MIB-OID: 1.3.6.1.4.1.231.2.10.2This section lists PCI HotPlug trap

Strona 23 - ServerView Event Manager 23

ServerView Event Manager 119Trap overview5.3.13 PRIMEPOWER trapsThis section describes the traps supplied with PRIMEPOWER.ADICLIBMIB-V2 traps (ADICLI

Strona 24 - 3.3 Filtering alarm entries

12 ServerView Event ManagerNotational conventions

Strona 25 - 3.4 Processing alarm entries

120 ServerView Event ManagerTrap overviewFSC-LOG3-MIB traps (log3v1.mib)MIB-OID: 1.3.6.1.4.1.231.2.46.2domNoManagementServer55 An agent was stopped.

Strona 26 - 3.4.4 Deleting alarms

ServerView Event Manager 121Trap overviewUNISERV-MIB traps (uniserv.mib)MIB-OID: 1.3.6.1.4.1.231.2.41PRIMEPOWER-XSCF-MIB traps (primepower_xscf.mib)M

Strona 27 - I Note for Linux

122 ServerView Event ManagerTrap overviewFSC-HACL-MIB traps (v1_fscHaCl.mib)MIB-OID: 1.3.6.1.4.1.231.2.42.2.0WSA-TRAP-MIB traps (wsatrap.mib)MIB-OID

Strona 28 - 3.6 Other settings

ServerView Event Manager 123Trap overviewwsaDROperationFinished313 DR operation was terminated.informationalwsaEnvironmentHardwareDefectSet301 Defect

Strona 29 - SC2 MIB traps

124 ServerView Event ManagerTrap overviewwsaLarHardwareErrorUnset4 A hardware error was repaired.informationalwsaLUNStateChanged 101 State of LUN ha

Strona 30

ServerView Event Manager 125Trap overview5.3.14 PXRE traps (dec.mib)MIB-OID: 1.3.6.1.4.1.36.2.15.21This section lists PXRE traps in alphabetical orde

Strona 31 - ServerView Event Manager 31

126 ServerView Event ManagerTrap overviewdiskFailureTrap 1 A disk drive has failed. The location of the disk is indicated by the disk name. Replace

Strona 32

ServerView Event Manager 127Trap overviewfanFailureTrap 5 The fan in the specified location has failed. Replace fan.majorfanInformationTrap 6 The fan

Strona 33 - ServerView Event Manager 33

128 ServerView Event ManagerTrap overviewpowerSupplyFailureTrap 3 The power supply in the specified location has failed. Replace power supply.majorp

Strona 34

ServerView Event Manager 129Trap overview5.3.15 RAID Adapter traps (Megaraid.mib)MIB-OID: 1.3.6.1.4.1.16.1.1.200This section lists RAID Adapter traps

Strona 35 - ServerView Event Manager 35

ServerView Event Manager 132Event ManagerThe Event Manager allows you to filter and forward alarm messages and specify the display.For monitoring, Se

Strona 36 - 36 ServerView Event Manager

130 ServerView Event ManagerTrap overviewrtConsistencyCorrected9011 Adapter-%d, Logical Drive-%d: Check consistency operation completed. Inconsisten

Strona 37 - 4 Alarm configuration

ServerView Event Manager 131Trap overviewrtPredictiveFailuresFalse9017 Adapter-%d, Channel-%d, Target-%d: Reported failure prediction threshold excee

Strona 38

132 ServerView Event ManagerTrap overview5.3.16 RomPilot traps (Rompilot.mib)MIB-OID: 1.3.6.1.4.1.2487This section lists RomPilot traps in alphabeti

Strona 39 - 4.1 Alarm rules

ServerView Event Manager 133Trap overview5.3.17 ServerControl traps (SC.mib)MIB-OID: 1.3.6.1.4.1.231.2.10.2This section lists ServerControl traps in

Strona 40 - 4.1.1 Managing alarm rules

134 ServerView Event ManagerTrap overviewnotEnoughCabinets 615 The actual number of storage extensions is lower than number stored in the configurat

Strona 41 - ServerView Event Manager 41

ServerView Event Manager 135Trap overviewsieScBootError 661 No bootable operating system can be found.informationalsieScBootWatchdogExpired662 Boot w

Strona 42

136 ServerView Event ManagerTrap overviewsieScUserAuthenticationFailure664 User authentication failure is detected via PPP, FTP, HTTP or telnet.majo

Strona 43 - 4.1.2 Assigning servers

ServerView Event Manager 137Trap overviewtempSensorBroken 630 The temperature sensor is defective or not connected.major tempSensorOk 635 The tempera

Strona 44

138 ServerView Event ManagerTrap overviewtrapOnBattery 606 AC power failure. Cabinet is running on battery power. The UPS is operating on battery po

Strona 45 - Figure 6: Server information

ServerView Event Manager 139Trap overview5.3.18 ServerControl traps (SC2.mib)MIB-OID: 1.3.6.1.4.1.231.2.10.2.2.10.20This section lists ServerControl

Strona 46

14 ServerView Event ManagerFirst-time startupCIM-Indications for VMware vSphere ESXi 5Events of servers with VMware vSphere ESXi 5 are provided as C

Strona 47 - 4.1.3 Assigning alarms

140 ServerView Event ManagerTrap overviewsc2TrapCabinetSwitchedOff2090 This trap will be sent when a cabinet is switched off. For obvious reasons it

Strona 48

ServerView Event Manager 141Trap overviewsc2TrapDcFail 2041 DC power failed in the specified cabinet. This is the result of the systems power-good se

Strona 49 - ServerView Event Manager 49

142 ServerView Event ManagerTrap overviewsc2TrapMessageLogFull2100 The System Event Log (message log) is full. No more messages can be logged. This

Strona 50

ServerView Event Manager 143Trap overviewsc2TrapRedundantFanFailed2015 The indicated redundant fan failed.major sc2TrapRedundantPowerSupplyFailed2035

Strona 51 - 4.1.4 Forwarding alarms

144 ServerView Event ManagerTrap overviewsc2TrapUncorrectableMemError2067 A uncorrectable memory error at unknown location was detected.criticalsc2T

Strona 52

ServerView Event Manager 145Trap overview5.3.19 ServerView traps (ServerView.mib)MIB-OID: 1.3.6.1.4.1.231.2.10.2This section lists ServerView traps i

Strona 53 - ServerView Event Manager 53

146 ServerView Event ManagerTrap overview5.3.20 ServerView status traps (Status.mib)MIB-OID: 1.3.6.1.4.1.231.2.10.2This section lists ServerView sta

Strona 54 - I ● Note for SMTP AUTH

ServerView Event Manager 147Trap overview5.3.21 Tape drive traps (tapealrt.mib)MIB-OID: 1.3.6.1.4.1.11.2.3.9.7.1This section lists tape drive traps i

Strona 55 - 4.2 Filter rules

148 ServerView Event ManagerTrap overviewtapeAlertTrap6 6 The tape is from a faulty batch or the tape drive is faulty:1. Use a good tape to test the

Strona 56 - 4.2.2 Filtering alarms

ServerView Event Manager 149Trap overviewtapeAlertTrap12 12 You have tried to load a cartridge of a type which is not supported by this drive.informa

Strona 57 - ServerView Event Manager 57

ServerView Event Manager 15Starting the Event Manager2.2 Starting the Event ManagerYou start the Event Manager either via the ServerView Operations M

Strona 58 - 4.3 Making settings

150 ServerView Event ManagerTrap overviewtapeAlertTrap19 19 The tape cartridge is nearing the end of its useful life. It is recommended that you:1.

Strona 59 - ServerView Event Manager 59

ServerView Event Manager 151Trap overviewtapeAlertTrap23 23 The last cleaning cartridge used in the tape drive was an invalid type:1. Do not use this

Strona 60

152 ServerView Event ManagerTrap overviewtapeAlertTrap32 32 The tape drive has a problem with the host interface: 1. Check the cables and cable conn

Strona 61 - ServerView Event Manager 61

ServerView Event Manager 153Trap overviewtapeAlertTrap39 39 The tape drive may have a hardware fault. Run extended diagnostics to verify and diagnose

Strona 62

154 ServerView Event ManagerTrap overviewtapeAlertTrap43 43 The operation has failed because the autoloader door is open:1. Clear any obstructions f

Strona 63 - ServerView Event Manager 63

ServerView Event Manager 155Trap overviewtapeAlertTrap256 256 The library mechanism is having difficulty communicating with the drive:1. Turn the lib

Strona 64

156 ServerView Event ManagerTrap overviewtapeAlertTrap260 260 The library mechanism may have a hardware fault. Run extended diagnostics to verify an

Strona 65 - ServerView Event Manager 65

ServerView Event Manager 157Trap overviewtapeAlertTrap266 266 The voltage supply to the library exceeds specifications. There is a potential problem

Strona 66

158 ServerView Event ManagerTrap overviewtapeAlertTrap271 271 The operation has failed because the library door is open:1. Clear any obstructions fr

Strona 67 - 4.6 Making pop-up settings

ServerView Event Manager 159Trap overviewtapeAlertTrap278 278 There is a potential problem with the barcode label or the scanner hardware in the libr

Strona 68 - I Notes for Linux

16 ServerView Event ManagerIcons2.3 IconsYou will find a list of the icons in the Alarm Monitor and Alarm Configuration windows and their meanings i

Strona 69 - (COM port and modem)

160 ServerView Event ManagerTrap overview5.3.22 Team Server traps (Fujitsu)This section describes the traps supplied with the Fujitsu Team Server.AS

Strona 70

ServerView Event Manager 161Trap overviewtrapPowerFanFail 14 Any power subsystem fan fails.majortrapPSFail 12 Any power supply fails. majortrapRPSFai

Strona 71 - ServerView Event Manager 71

162 ServerView Event ManagerTrap overviewLDCM MIB traps (Ldcm.mib) MIB-OID: 1.3.6.1.4.1.343.2.5.1.2LDSM MIB traps (Ldsm.mibMIB-OID: 1.3.6.1.4.1.343.

Strona 72 - 4.8 Making execute settings

ServerView Event Manager 163Trap overview5.3.23 Threshold traps (Trap.mib)MIB-OID: 1.3.6.1.4.1.231This section lists threshold traps in alphabetical

Strona 73 - ServerView Event Manager 73

164 ServerView Event ManagerTrap overviewsniInvTrapValid 133 Threshold has become valid.informational sniNTAlert 304 NT alert message was written to

Strona 74 - 4.9 Making broadcast settings

ServerView Event Manager 165Trap overviewsniNTLoginUser 301 User logged into server. informationalsniNTRegChangeAttr 311 Attributes for a key or its

Strona 75 - ServerView Event Manager 75

166 ServerView Event ManagerTrap overviewsniNWDataMigration 041 A files data has been migrated.informationalsniNWDataDeMigration 042 Migration of fi

Strona 76

ServerView Event Manager 167Trap overviewsniNWNoRelinquishControl023 NLM-Module has not relinquished control.criticalsniNWOpenScreen 020 Screen was o

Strona 77 - 4.10 Making trap settings

168 ServerView Event ManagerTrap overview5.3.24 UPS traps (Upsman.mib)MIB-OID: 1.3.6.1.4.1.1356This section lists UPS traps in alphabetical order.UP

Strona 78

ServerView Event Manager 169Trap overviewUPS traps 2Trap name ID Meaning Error classboostOn 6 The UPS has turned on the booster.majorcommunicationEst

Strona 79 - 4.11 Macros

ServerView Event Manager 17IconsYellow: Forwarding completedRed: Forwarding present (still active)Table columns can be filtered according to differen

Strona 80

170 ServerView Event ManagerTrap overview

Strona 81 - ServerView Event Manager 81

ServerView Event Manager 1716 MIB integrationThe Web-based MIB Manager tool is installed automatically when you install the Event Manager under Windo

Strona 82

172 ServerView Event ManagerMIB integrationThe tool starts up and the following window is displayed:Figure 15: “MIB Manager” toolTo integrate privat

Strona 83 - ServerView Event Manager 83

ServerView Event Manager 173MIB integrationUpdating integrated MIB filesYou can update integrated MIB files. The name of the updated integrated MIB f

Strona 84

174 ServerView Event ManagerMIB integration

Strona 85 - Displaying trap information

18 ServerView Event ManagerIcons

Strona 86 - 5.3 Trap overview

ServerView Event Manager 193 Alarm MonitorThe Alarm Monitor component displays all received alarms relating to the selected servers and server groups

Strona 87

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our

Strona 88 - 88 ServerView Event Manager

20 ServerView Event ManagerViewing alarmsThe window is divided into four sections:● The menu bar below the title bar allows you to navigate between

Strona 89

ServerView Event Manager 21Viewing alarmsBelow the status bar the alarm entries are displayed with the following information:Receive TimeTime when th

Strona 90 - 90 ServerView Event Manager

22 ServerView Event ManagerViewing alarmsThe icons have the following meanings:● In the bottom right section of the window you can find out informat

Strona 91

ServerView Event Manager 23Viewing alarmsIf the server is in the server list, you can use the Edit Server Settings link to open the Server Properties

Strona 92 - Table 20: APC traps

24 ServerView Event ManagerViewing alarms for a server3.2 Viewing alarms for a serverIf several alarm messages have been received for a server, the

Strona 93 - ServerView Event Manager 93

ServerView Event Manager 25Processing alarm entries3.4 Processing alarm entriesThe following functions are available for processing the alarm entries

Strona 94

26 ServerView Event ManagerProcessing alarm entriesI When the server starts up, a RAID manager or Ethernet card, etc. may issue an alarm (SNMP trap)

Strona 95 - Table 21: Blade System Traps

ServerView Event Manager 27Testing the connection3.5 Testing the connectionTo test the connection to a specific server, you can send a trap. Proceed

Strona 96

28 ServerView Event ManagerOther settings3.6 Other settings3.6.1 Editing an alarm noteYou can edit the note displayed for an alarm entry:Ê Click the

Strona 97 - ServerView Event Manager 97

ServerView Event Manager 29iRMC S2/S3 SEL Entries and SC2 MIB Traps3.7 iRMC S2/S3 SEL entries relayed as SC2 MIB trapsI The following table applies t

Strona 98

ServerView Event Manager Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.1 Changes from

Strona 99 - ServerView Event Manager 99

30 ServerView Event ManageriRMC S2/S3 SEL Entries and SC2 MIB Traps040003 ’FAN XY’: Redundant fan failedThe redundant fan ’FAN XY’ failed in cabinet

Strona 100 - Table 22: Cluster traps

ServerView Event Manager 31iRMC S2/S3 SEL Entries and SC2 MIB Traps070001 ’PSU XY’: Power supply OKPower supply ’PSU XY’ in cabinet XY at server XY w

Strona 101 - ServerView Event Manager 101

32 ServerView Event ManageriRMC S2/S3 SEL Entries and SC2 MIB Traps07000A ’PSU XY’: Power supply critical temperatureTemperature at power supply ’PS

Strona 102

ServerView Event Manager 33iRMC S2/S3 SEL Entries and SC2 MIB Traps120030 PCI system error (SERR): Slot 0x%1The system wa restarted after a severe pr

Strona 103 - 5.3.5 DPT traps (dptscsi.mib)

34 ServerView Event ManageriRMC S2/S3 SEL Entries and SC2 MIB Traps150031 Battery voltage ’BATT XY’ low warning: % VoltBattery voltage ’BATT XY’ in

Strona 104 - Table 23: DPT traps

ServerView Event Manager 35iRMC S2/S3 SEL Entries and SC2 MIB Traps190017 ’DIMM XY’: Memory replaced by spare memoryMemory module ’DIMM XY’ in cabine

Strona 105 - Table 24: DDM-Traps

36 ServerView Event ManageriRMC S2/S3 SEL Entries and SC2 MIB Traps

Strona 106

ServerView Event Manager 374 Alarm configurationThe Alarm Configuration component in the Event Manager is used to define settings for alarm handling.

Strona 107 - ServerView Event Manager 107

38 ServerView Event ManagerAlarm configurationThe first time the window opens, the right-hand section shows the Alarm Rules – Manage Alarm Rules dia

Strona 108

ServerView Event Manager 39Alarm rules4.1 Alarm rulesAn alarm rule forwards alarms from various servers to one or more destinations. A complete defin

Strona 109 - Table 25: DuplexWrite traps

ServerView Event ManagerContents4 Alarm configuration . . . . . . . . . . . . . . . . . . . . . . . 374.1 Alarm rules . . .

Strona 110

40 ServerView Event ManagerAlarm rules4.1.1 Managing alarm rulesThe Alarm Rules – Manage Alarm Rules screen provides an overview of all defined alar

Strona 111 - Table 26: Hard disk traps

ServerView Event Manager 41Alarm rulesAlarm Rules tabThe Alarm Rules tab is used to assign alarm rules to alarms, servers and alarm destinations.The

Strona 112 - 5.3.9 Generic traps

42 ServerView Event ManagerAlarm rulesServers tabThe Servers tab shows you which servers are covered by which alarm rules. Here you can check whethe

Strona 113 - Table 28: MultiPath traps

ServerView Event Manager 43Alarm rules4.1.2 Assigning serversIn the Alarm Rules – Assign Server screen, you define the servers and/or server groups t

Strona 114 - Table 29: Mylex traps

44 ServerView Event ManagerAlarm rulesI Because different server groups can have the same name, they are displayed in the Alarm Configuration compon

Strona 115 - ServerView Event Manager 115

ServerView Event Manager 45Alarm rules4.1.2.1 Displaying server informationIf you select Show Information about Server from the context menu,the Serv

Strona 116

46 ServerView Event ManagerAlarm rulesI You can start Operations Manager for the selected server in this window. To do this, click the status icon i

Strona 117 - ServerView Event Manager 117

ServerView Event Manager 47Alarm rules4.1.3 Assigning alarmsIn the Alarm Rules – Assign Alarms dialog box you can define in the Individual Alarms dia

Strona 118 - Table 30: PCI HotPlug traps

48 ServerView Event ManagerAlarm rulesThe alarm list in the bottom section of the window shows via checkboxes which alarms are assigned to the alarm

Strona 119 - 5.3.13 PRIMEPOWER traps

ServerView Event Manager 49Alarm rulesThe alarm list offers a context menu, in which you can select the following items:Show information about select

Strona 120 - Table 32: DOMAIN-MIB traps

ServerView Event Manager Contents5.3.7 DuplexWrite traps (DW.mib) . . . . . . . . . . . . . . . . . . . 1095.3.8 Hard disk (S.M.A.

Strona 121 - Table 34: UNISERV-MIB traps

50 ServerView Event ManagerAlarm rulesThe top drop-down list contains the names of all known alarm rules. Here you can select the alarm rule that yo

Strona 122 - Table 37: WSA-TRAP-MIB traps

ServerView Event Manager 51Alarm rules4.1.4 Forwarding alarmsIn the Alarm Rules – Assign Destinations screen you can make settings relating to alarm

Strona 123 - ServerView Event Manager 123

52 ServerView Event ManagerAlarm rulesYou can use the following buttons to activate or deactivate the forwarding of an alarm:>Activates the selec

Strona 124

ServerView Event Manager 53Alarm rulesBy clicking the Add button you can define a new destination. The following window opens showing the available d

Strona 125 - 5.3.14 PXRE traps (dec.mib)

54 ServerView Event ManagerAlarm rulesI ● Note for SMTP AUTHFor sending mails, SMTP AUTH is supported. The supported authentication method is: CRAM

Strona 126 - Table 38: PXRE traps

ServerView Event Manager 55Filter rules4.2 Filter rulesThe filter rules define the servers or server groups from which you want to filter out alarms

Strona 127 - ServerView Event Manager 127

56 ServerView Event ManagerFilter rules4.2.2 Filtering alarmsIn the Filter Rules – Alarm Filtering dialog box you can activate or deactivate filter

Strona 128

ServerView Event Manager 57Filter rulesIn the input field Set time for repetition in seconds you can specify the interval after which the same alarm

Strona 129 - Table 39: RAID Adapter traps

58 ServerView Event ManagerMaking settings4.3 Making settingsIn the General Settings screen you can define general settings for alarm handling.You c

Strona 130

ServerView Event Manager 59Mail forwarding in general4.4 Mail forwarding in generalMaking mail settingsIf you have selected Mail for the forwarding,

Strona 131 - ServerView Event Manager 131

ServerView Event ManagerContents

Strona 132 - Table 40: ROMPilot traps

60 ServerView Event ManagerMail forwarding in generalMail Settings tabThe Mail Settings tab provides fields for the mail settings, some of which alr

Strona 133 - ServerView Event Manager 133

ServerView Event Manager 61Mail forwarding in generalMail Properties tabThe Mail Properties tab provides fields for the mail server. The mail server

Strona 134

62 ServerView Event ManagerMail forwarding in generalTime Model Settings tabThe Time Model Settings tab allows you to select, add or modify a time m

Strona 135 - ServerView Event Manager 135

ServerView Event Manager 63Mail and Execute forwarding to the service provider4.5 Mail and Execute forwarding to the service providerThe Event Manage

Strona 136

64 ServerView Event ManagerMail and Execute forwarding to the service providerYou can enable or disable this configuration with the Enabled option.T

Strona 137 - ServerView Event Manager 137

ServerView Event Manager 65Mail and Execute forwarding to the service providerThe Exec Settings tab offers fields for execute settings, some of which

Strona 138

66 ServerView Event ManagerMail and Execute forwarding to the service providerIf you click the Test Address button in the Service Mail Settings wind

Strona 139 - ServerView Event Manager 139

ServerView Event Manager 67Making pop-up settings4.6 Making pop-up settingsIf you have selected Popup for the forwarding, the New Popup Configuration

Strona 140

68 ServerView Event ManagerMaking pop-up settingsI Notes for Linux1. To receive the forwarded alarm messages, a user must be logged onto the Linux s

Strona 141 - ServerView Event Manager 141

ServerView Event Manager 69Making pager settings (COM port and modem)4.7 Making pager settings (COM port and modem)If you have selected Pager for the

Strona 142

ServerView Event Manager 71 IntroductionThe ServerView Event Manager (called simply Event Manager below) is a component of the Event Management of th

Strona 143 - ServerView Event Manager 143

70 ServerView Event ManagerMaking pager settings (COM port and modem)Time Model Time model indicating when an alarm is to be forwarded. Select a pre

Strona 144

ServerView Event Manager 71Making pager settings (COM port and modem)You specify the pager service via the Pager, SMS-1 or SMS-2 tabs.The Server Num

Strona 145 - Table 43: ServerView traps

72 ServerView Event ManagerMaking execute settings4.8 Making execute settingsIf you have selected Execute for the forwarding, the New Execute Config

Strona 146

ServerView Event Manager 73Making execute settingsTime Model Settings tabThe Time Model Settings tab allows you to select, add or modify a time model

Strona 147 - Table 45: Tape traps

74 ServerView Event Manager4.9 Making broadcast settingsBroadcast is a type of transmission whereby a pop-up window or a message is displayed on mul

Strona 148

ServerView Event Manager 75Making broadcast settingsTime Model Settings tabThe Time Model Settings tab allows you to select, add or modify a time mod

Strona 149 - ServerView Event Manager 149

76 ServerView Event ManagerMaking broadcast settingsI Notes for LinuxThe forwarding service uses the database under /var/run/utmp (utmp(5)) to obtai

Strona 150

ServerView Event Manager 77Making trap settings4.10 Making trap settingsIf you have selected Station for the forwarding, the New Station Configuratio

Strona 151 - ServerView Event Manager 151

78 ServerView Event ManagerMaking trap settingsTime Model Settings tabThe Time Model Settings tab allows you to select, add or modify a time model.

Strona 152

ServerView Event Manager 79Macros4.11 MacrosBelow is a list of macros that can be used for the forwarding of alarms (e.g. Mail, Pager).These macros a

Strona 153 - ServerView Event Manager 153

8 ServerView Event ManagerChanges from the previous version1.1 Changes from the previous versionThis edition is valid for the Event Manager of Server

Strona 154

80 ServerView Event ManagerAlarm configuration example4.12 Alarm configuration exampleThis section explains a typical example of alarm configuration

Strona 155 - ServerView Event Manager 155

ServerView Event Manager 81Alarm configuration exampleÊ Click Apply, then click Next.The Assign Alarms - Individual Alarms window opens.Ê Click Next

Strona 156

82 ServerView Event ManagerAlarm configuration exampleÊ Click Apply, then click Test Address.Ê Once the test mail is sent successfully, click OK. Th

Strona 157 - ServerView Event Manager 157

ServerView Event Manager 835TrapsIf a special event occurs in a network component, then the SNMP agent can send a message to one or more managers to

Strona 158

84 ServerView Event ManagerDisplaying trap informationÊ Under Alarms, select the Agent Alarm Information option.I The trap information can also be c

Strona 159 - ServerView Event Manager 159

ServerView Event Manager 85Displaying trap informationWhen you select a MIB, a window with detailed trap information will open; the window will look

Strona 160

86 ServerView Event ManagerDisplaying traps in the Windows event log5.2 Displaying traps in the Windows event logWhen you install the Windows agents

Strona 161 - ServerView Event Manager 161

ServerView Event Manager 87Trap overviewbaspTrap.mib Broadcom Advanced Server trapsBIOS.mibBUS.mibclariion1.mib FibreCatclariion_fsc_2.mib FibreCatCm

Strona 162 - Table 48: LDSM MIB traps

88 ServerView Event ManagerTrap overviewLdcm.mib LAN Desk Client Manager from Intel traps see page 162Ldsm.MIB LAN Desk Server Manager from Intel tr

Strona 163 - Table 49: Threshold traps

ServerView Event Manager 89Trap overviewPSA-LinBcm5700Trap-MIB.mibPRIMEQUEST trapsPSA-LinEmulexTrap-MIB.mibPRIMEQUEST trapsPSA-LinGdsTrap-MIB.mibPRIM

Strona 164

ServerView Event Manager 9ServerView Suite link collection1.2 ServerView Suite link collectionVia the link collection, Fujitsu Technology Solutions p

Strona 165 - ServerView Event Manager 165

90 ServerView Event ManagerTrap overviewPSA-WinIntelE100Trap-MIB.mibPRIMEQUEST trapsPSA-WinLsiLogicTrap-MIB.mibPRIMEQUEST trapsRAID.mibRFC1157.mibRF

Strona 166

ServerView Event Manager 91Trap overviewServerView.mib ServerView traps see page 145Status.mib ServerView status traps see page 146tapealrt.mib Tape

Strona 167 - ServerView Event Manager 167

92 ServerView Event ManagerTrap overview5.3.1 Adaptec traps (Duralink.mib)MIB-OID: 1.3.6.1.4.1.795.3.1.2.3This section lists Adaptec traps in alphab

Strona 168 - 5.3.24 UPS traps (Upsman.mib)

ServerView Event Manager 93Trap overviewcommunicationEstablished8 Communication is established between the agent and power supply.informational commu

Strona 169 - Table 51: UPS traps 2

94 ServerView Event ManagerTrap overviewsoftwareBypass 21 The UPS has been set to bypass by a user via software or via the UPS front panel.minorswit

Strona 170 - Trap overview

ServerView Event Manager 95Trap overview5.3.3 Blade System traps (s31.mib)MIB-OID: 1.3.6.1.4.1.7244.1.1.1This section lists the blade system traps in

Strona 171 - I Please note:

96 ServerView Event ManagerTrap overviews31ServerBladeError 1609 The server blade status at the blade system is error.critical s31ServerBladeHotRepl

Strona 172 - Figure 15: “MIB Manager” tool

ServerView Event Manager 97Trap overviews31SwitchBladeAdded 1611 A switch blade was added to the blade system.informationals31SwitchBladeCriticalErro

Strona 173 - ServerView Event Manager 173

98 ServerView Event ManagerTrap overviews31SysPowerSupplyRemoved1627 A power supply unit was removed from the blade system.informationals31SysTempCr

Strona 174 - MIB integration

ServerView Event Manager 99Trap overviews31TrapEventLog 1638 An error was recorded on the blade system. See the server management event error log (Re

Komentarze do niniejszej Instrukcji

Brak uwag