Parameter Data Formats
4 - 20 C141-E167
Bit
Byte
76543210
0 00000111
1 X‘0A’ (Page Length)
2 (Reserved) EER PER DTE DCR
Default00001000
Variable00001111
3 Number of retries during VERIFY.
Default X‘3F’
Variable X‘FF’
4 Correctable Bit Length
Default X‘E9’ (=233 bits)
Variable X‘00’
5-9 X‘0000000000’ (Reserved)
10-11 Recovery Time Limit
Default X‘7530’
Variable X‘FFFF’
Figure 4.5 MODE SELECT parameters: verify error recovery parameters
The error recovery parameters divided in this page descriptor are applicable for the following
commands.
VERIFY
WRITE AND VERIFY (verify operation)
Note:
If selecting the SCSI-1/CCS mode in the CHANGE DEFINITION command specification, use
Page code = 1 (Read/Write Error Recovery Parameters) instead of this parameter.
a. Error recovery flags
EER (enable early recovery)
PER (post error)
DTE (disable transfer on error)
DCR (disable correction)
The definitions and functions of these control flags are the same as for the read/write error
recovery parameters. See item (1) concerning the details.
(See the
Note.)