Strona 1 - PRIMERGY TX300 S6 Server

Options Guide - EnglishPRIMERGY TX300 S6 Server Options GuideEdition August 2010

Strona 2 - Copyright and Trademarks

Options Guide TX300 S6Contents

Strona 3 - Before reading this manual

100 Options Guide TX300 S6Conversion from a floorstand model to a rack modelÊ If necessary, lay the server on its right-hand side. Get a second person

Strona 4

TX300 S6 Options Guide 101Conversion from a floorstand model to a rack modelÊ Slide the foot mounting rail backward (2) until the hooks (a) disengage.

Strona 5 - TX300 S6 Options Guide

102 Options Guide TX300 S6Conversion from a floorstand model to a rack modelÊ Turn the dummy covers removed beforehand through 90° to the left.Ê Insta

Strona 6

TX300 S6 Options Guide 103Conversion from a floorstand model to a rack modelFigure 76: Fastening the rail adapter (shown rail adapter left)Ê Fasten th

Strona 7

104 Options Guide TX300 S6Conversion from a floorstand model to a rack modelTo enable the rack model to be shown correctly in ServerView Management us

Strona 8

TX300 S6 Options Guide 10511 CompletionV CAUTION!Follow the safety instructions in the chapter "Safety instructions" on page 19.11.1 Instal

Strona 9

106 Options Guide TX300 S6Installing the fan carrier CompletionFigure 79: Connecting the power cableÊ Fasten the fan carrier with thethree knurled scr

Strona 10 - Contents

TX300 S6 Options Guide 107Completion Floorstand model11.2 Floorstand model11.2.1 Mounting the server feetFigure 80: Mounting the server feetÊ If requi

Strona 11 - 1 Preface

108 Options Guide TX300 S6Floorstand model Completion11.2.2 Attaching the front coverReattach the front cover after installing/removing accessible dri

Strona 12

TX300 S6 Options Guide 109Completion Floorstand modelFigure 83: Attaching the HDD coverÊ Hook the drive cover in place at the top and press it against

Strona 13 - TX300 S6 Options Guide 13

TX300 S6 Options Guide 111 PrefaceWith top dual processor performance, the PRIMERGY TX300 S6 tower server is an all-purpose server for medium sized co

Strona 14

110 Options Guide TX300 S6Floorstand model Completion11.2.3 Closing the serverI The left side cover closes easily when the server is in the horizontal

Strona 15

TX300 S6 Options Guide 111Completion Rack model11.3 Rack model11.3.1 Attaching the rack front coverReattach the rack front cover after implementing th

Strona 16 - 1.4 Notational conventions

112 Options Guide TX300 S6Rack model Completion11.3.2 Closing the serverÊ Pull the locking lever as far as it will go and insert the top cover (see al

Strona 17

TX300 S6 Options Guide 113Completion Rack modelFigure 87: Inserting the server (b)Ê Extend the telescopic rails completely to the front (1).I They mus

Strona 18 - Procedure

114 Options Guide TX300 S6Rack model Completion

Strona 19

TX300 S6 Options Guide 11512 Appendix12.1 CablingYou will find suggestions for cabling on the next pages.

Strona 20

116 Options Guide TX300 S6Cabling AppendixFigure 88: Server with 3.5-inch SAS HDDs and 3.5-inch SAS HDD extension boxLegend:PowerSAS/SATAUSB / VGAData

Strona 21

TX300 S6 Options Guide 117Appendix CablingFigure 89: Server with 3.5-inch SAS HDDs and SAS backupLegend:PowerSAS/SATAUSB / VGADataCOM 1COM 2USBUSBVGAC

Strona 22

118 Options Guide TX300 S6Cabling AppendixFigure 90: Server with 3.5-inch SAS HDDs and USB backupLegend:PowerSAS/SATAUSB / VGADataCOM 1COM 2USBUSBVGAC

Strona 23

TX300 S6 Options Guide 119Appendix CablingFigure 91: Server with 2.5-inch SAS HDDs and 2.5-inch HDD extension boxLegend:PowerSAS/SATAUSB / VGADataCOM

Strona 24

12 Options Guide TX300 S6Concept and target groups Preface1.1 Concept and target groupsThis Options Guide shows you how to extend and upgrade your ser

Strona 25

120 Options Guide TX300 S6Cabling AppendixFigure 92: Server with 2.5-inch SAS HDDs (onboard SAS) and 2.5-inch HDD extension boxLegend:PowerSAS/SATAUSB

Strona 26

TX300 S6 Options Guide 121IndexAaccessible drivesattaching EasyClick rails 58detaching EasyClick rails 57DVD burner 14DVD drive 14equipping bays 54, 5

Strona 27

122 Options Guide TX300 S6Indexinstalling LSP 60Multibay 2 68installing 70Nnotational conventions 16Rrack front coverattaching 111removing 34rack mode

Strona 28 - 4.1 Floorstand model

TX300 S6 Options Guide 13Preface Documentation overviewI PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2. The ServerView S

Strona 29 - TX300 S6 Options Guide 29

14 Options Guide TX300 S6Expansions and conversions Preface1.3 Expansions and conversionsMain memoryThe system board offers 18 slots for memory module

Strona 30 - Floorstand model Preparation

TX300 S6 Options Guide 15Preface Expansions and conversionsLSD/LSPThe system board supports the CSS (Customer Self Service) functionality (description

Strona 31 - Preparation Floorstand model

16 Options Guide TX300 S6Notational conventions Preface– If a failure occurs, please inform your service about the TPM activation before it takes any

Strona 32

TX300 S6 Options Guide 172ProcedureV CAUTION!● The actions described in this manual shall be performed by technical specialists. A technical speciali

Strona 33

18 Options Guide TX300 S6Procedure

Strona 34

TX300 S6 Options Guide 193 Safety instructionsI The following safety instructions are also provided in the manual "Safety Notes and Regulations&

Strona 35 - 4.3 Removing the fan carrier

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our

Strona 36

20 Options Guide TX300 S6Safety instructionsBefore starting upV CAUTION!● During installation and before operating the device, observe the instruction

Strona 37

TX300 S6 Options Guide 21Safety instructionsV CAUTION!● Ensure that the power sockets on the device and the properly grounded power outlets are freel

Strona 38 - 5.1 Memory modules

22 Options Guide TX300 S6Safety instructionsV CAUTION!● Proper operation of the system (in accordance with IEC 60950-1/2 resp. EN 60950-1/2) is only

Strona 39 - TX300 S6 Options Guide 39

TX300 S6 Options Guide 23Safety instructionsV CAUTION!● Install the screw removed during installation/detaching Internal Options in former device/pos

Strona 40 - 5.2 Expanding the main memory

24 Options Guide TX300 S6Safety instructions● Shocks and vibrations are also to be avoided.● Do not insert any objects other than the specified CDs/DV

Strona 41

TX300 S6 Options Guide 25Safety instructionsI You can prevent damage from the optical drive and the CDs/DVDs/BDs, as well as premature wear of the di

Strona 42

26 Options Guide TX300 S6Safety instructions● Wear a suitable grounding cable that connects you to the external chassis of the system unit.● Always ho

Strona 43 - TX300 S6 Options Guide 43

TX300 S6 Options Guide 274 PreparationV CAUTION!● Before removing or attaching covers, turn off the server, all peripheral devices, and any other conn

Strona 44

28 Options Guide TX300 S6Floorstand model Preparation4.1 Floorstand modelI For some expansions and conversions, it is advisable to lay the server on i

Strona 45

TX300 S6 Options Guide 29Preparation Floorstand model4.1.2 Removing the front coverRemove the front cover when making the following routines:– Install

Strona 46

TX300 S6 Options GuideBefore reading this manualFor your safetyThis manual contains important information for safely and correctly using this product.

Strona 47

30 Options Guide TX300 S6Floorstand model PreparationFigure 4: Pulling out the locking buttonsÊ Pull out the two green locking buttons (1).Figure 5: R

Strona 48

TX300 S6 Options Guide 31Preparation Floorstand model4.1.3 Removing the server feetFigure 6: Removing the server feetÊ If necessary, remove the server

Strona 49

32 Options Guide TX300 S6Rack model Preparation4.2 Rack modelÊ Terminate all applications and shut down the server correctly.Ê If your operating syste

Strona 50 - 50 Options Guide TX300 S6

TX300 S6 Options Guide 33Preparation Rack modelRemoving the server from the rack and opening the serverDepending on how accessible the server is in th

Strona 51 - TX300 S6 Options Guide 51

34 Options Guide TX300 S6Rack model Preparation4.2.2 Removing the rack front coverYou remove the rack front cover when making the following routines:–

Strona 52 - 6.3 Replacing the heat sink

TX300 S6 Options Guide 35Preparation Removing the fan carrier4.3 Removing the fan carrierFigure 10: Disconnecting the power cableÊ Disconnect the powe

Strona 53

36 Options Guide TX300 S6Removing the fan carrier PreparationFigure 11: Removing the fan carrierÊ Push the fan carrier in the direction of the front s

Strona 54 - 7.1 Equipping of the bays

TX300 S6 Options Guide 375Main memoryV CAUTION!● Before installing/removing memory to/from the server, turn off the server, all peripheral devices, an

Strona 55 - Options Guide 55

38 Options Guide TX300 S6Memory modules Main memory5.1 Memory modulesThe system board offers 18 slots for memory modules. 9 memory slots can be used i

Strona 56

TX300 S6 Options Guide 39Main memory Memory modulesFigure 12: Extract from the configurator (EMEA market)I The current configurator can be found unde

Strona 57

Options Guide TX300 S6These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control,

Strona 58

40 Options Guide TX300 S6Expanding the main memory Main memory5.2 Expanding the main memoryÊ Open the server and remove the fan carrier as described i

Strona 59 - 7.3 Multibay 1

TX300 S6 Options Guide 416 ProcessorsV CAUTION!● Before installing/removing processors to/from the server, turn off the server, all peripheral devices

Strona 60 - 60 Options Guide TX300 S6

42 Options Guide TX300 S6Installing a second processor Processors6.1 Installing a second processorThe system board can be upgraded with a second proce

Strona 61 - TX300 S6 Options Guide 61

TX300 S6 Options Guide 43Processors Installing a second processorFigure 16: Opening the processor holder and removing the socket coverÊ Press the spri

Strona 62 - Appendix)

44 Options Guide TX300 S6Installing a second processor ProcessorsFigure 17: Inserting and locking the processorÊ Hold the processor between your thumb

Strona 63 - TX300 S6 Options Guide 63

TX300 S6 Options Guide 45Processors Installing a second processorFigure 18: Removing the protective coverÊ Remove the protective cover on the undersid

Strona 64 - 7.3.2 Installing Multibay 1

46 Options Guide TX300 S6Installing a second processor ProcessorsFigure 19: Mounting and locking the heat sinkÊ Align the heat sink on the processor s

Strona 65 - Options Guide 65

TX300 S6 Options Guide 47Processors Replacing the processor6.2 Replacing the processorV CAUTION!Only processors of the same type may be used on the sy

Strona 66 - 66 Options Guide TX300 S6

48 Options Guide TX300 S6Replacing the processor ProcessorsRemoving an old processorFigure 21: Removing an old processorÊ Press the spring clip downwa

Strona 67 - C cable to the LSP/LSD

TX300 S6 Options Guide 49Processors Replacing the processorInserting and locking a new processorFigure 22: Inserting and locking a new processorÊ Hold

Strona 68

TX300 S6 Options GuideOnly for the Japanese market:I Although described in this manual, some sections do not apply to the Japanese market. These optio

Strona 69 - 7.4.1 Multibay 2

50 Options Guide TX300 S6Replacing the processor ProcessorsFigure 23: Applying and distributing thermal pasteÊ Apply a small amount of thermal paste t

Strona 70

TX300 S6 Options Guide 51Processors Replacing the processorMounting and locking the heat sinkFigure 24: Mounting and locking the heat sinkÊ Align the

Strona 71 - Figure 44: Cabling SAS cable

52 Options Guide TX300 S6Replacing the heat sink Processors6.3 Replacing the heat sinkÊ Open the server and remove the fan carrier as described in the

Strona 72

TX300 S6 Options Guide 537 Accessible drives and LSD/LSPV CAUTION!● Before installing/removing an accessible drive to/from the server, turn off the se

Strona 73 - TX300 S6 Options Guide 73

54 Options Guide TX300 S6Equipping of the bays Accessible drives and LSD/LSP7.1 Equipping of the baysThree 5.25-inch bays are available for accessible

Strona 74

TX300 S6 Options Guide 55Accessible drives and LSD/LSP Equipping of the baysRecommended equipping of the bays: Order Installed accessible driveBay Max

Strona 75

56 Options Guide TX300 S6Accessible 5.25-inch drive Accessible drives and LSD/LSP7.2 Accessible 5.25-inch driveÊ Open the server and remove the the fr

Strona 76

TX300 S6 Options Guide 57Accessible drives and LSD/LSP Accessible 5.25-inch driveFigure 27: Detaching the EasyClick rails from the dummy coverÊ Detach

Strona 77

58 Options Guide TX300 S6Accessible 5.25-inch drive Accessible drives and LSD/LSP7.2.2 Installing an accessible 5.25-inch driveFigure 28: Attaching th

Strona 78

TX300 S6 Options Guide 59Accessible drives and LSD/LSP Multibay 17.3 Multibay 1Ê Open the server and remove the the front cover or the rack front cove

Strona 79

Options Guide TX300 S6

Strona 80

60 Options Guide TX300 S6Multibay 1 Accessible drives and LSD/LSPFigure 30: Sliding the LSP in the 3.5-inch frameÊ Slide the LSD/LSP in the 3.5-inch f

Strona 81 - Options Guide 81

TX300 S6 Options Guide 61Accessible drives and LSD/LSP Multibay 1Figure 32: Fastening the 3.5-inch frame with LSP in Multibay 1Ê Fasten the 3.5-inch f

Strona 82

62 Options Guide TX300 S6Multibay 1 Accessible drives and LSD/LSPFigure 34: Connecting the PS adapter cable to the DVD driveÊ Connect the PS adapter c

Strona 83 - Options Guide 83

TX300 S6 Options Guide 63Accessible drives and LSD/LSP Multibay 1Figure 35: Inserting the DVD drive module in the Multibay 1Ê From the front, insert t

Strona 84 - (see circle)

64 Options Guide TX300 S6Multibay 1 Accessible drives and LSD/LSP7.3.2 Installing Multibay 1Figure 37: Connecting the SATA cable to the DVD driveÊ Pul

Strona 85 - Options Guide 85

TX300 S6 Options Guide 65Accessible drives and LSD/LSP Multibay 1Figure 38: Installing Multibay 1Ê Push Multibay 1 fully into bay 3 until the EasyClic

Strona 86 - (1 + 2)

66 Options Guide TX300 S6Multibay 1 Accessible drives and LSD/LSPFigure 39: Connecting the PS adapter cable to the power cableÊ Connect the PS adapter

Strona 87 - TX300 S6 Options Guide 87

TX300 S6 Options Guide 67Accessible drives and LSD/LSP Multibay 1Figure 41: Connecting the I2C cable to the LSP/LSDÊ Remove the cable tie of the I2C c

Strona 88

68 Options Guide TX300 S6HDD extension box Accessible drives and LSD/LSP7.4 HDD extension boxIn the base units two 5.25-inch bays for accessible drive

Strona 89 - TX300 S6 Options Guide 89

TX300 S6 Options Guide 69Accessible drives and LSD/LSP HDD extension box7.4.1 Multibay 2Multibay 2 contains one bay for a LSP or LSD, one bay for a DV

Strona 90 - 90 Options Guide TX300 S6

TX300 S6 Options GuideContents1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111.1 Concept and ta

Strona 91 - TX300 S6 Options Guide 91

70 Options Guide TX300 S6HDD extension box Accessible drives and LSD/LSP7.4.1.1 Installing Multibay 2When installing Multibay 2, proceed in a similar

Strona 92 - 92 Options Guide TX300 S6

TX300 S6 Options Guide 71Accessible drives and LSD/LSP HDD extension boxFigure 44: Cabling SAS cableÊ Connect the SAS cable included to the connector

Strona 93

72 Options Guide TX300 S6HDD extension box Accessible drives and LSD/LSPÊ Close the server, connect it to the power outlet, and switch it on as descri

Strona 94 - TPM Further options

TX300 S6 Options Guide 73Accessible drives and LSD/LSP HDD extension box7.4.2.1 Installing 2.5 inch HDD extension boxFigure 46: Connecting PS adapter

Strona 95 - Figure 67: Securing the TPM

74 Options Guide TX300 S6HDD extension box Accessible drives and LSD/LSPFigure 47: Cabling 2.5-inch HDD extension boxÊ Connect the PS adapter cables t

Strona 96 - 9.2 USB Flash Module (UFM)

TX300 S6 Options Guide 758 Expansion cards and BBUV CAUTION!● Before installing/removing expansion cards to/from the server, turn off the server, all

Strona 97 - TX300 S6 Options Guide 97

76 Options Guide TX300 S6Installing expansion cards Expansion cards and BBU8.1 Installing expansion cardsThe system board has seven PCI Express slots.

Strona 98 - 98 Options Guide TX300 S6

TX300 S6 Options Guide 77Expansion cards and BBU Installing expansion cardsÊ Open the server as described in the chapter "Preparation" on pa

Strona 99

78 Options Guide TX300 S6Installing expansion cards Expansion cards and BBUFigure 50: Installing an expansion cardÊ Carefully press the new expansion

Strona 100 - TX300 S6

TX300 S6 Options Guide 79Expansion cards and BBU Installing a BBU8.2 Installing a BBUV CAUTION!● Do not connect the cable using excessive force, the c

Strona 101 - TX300 S6 Options Guide 101

Options Guide TX300 S6Contents6 Processors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 416.1 Installing a secon

Strona 102

80 Options Guide TX300 S6Installing a BBU Expansion cards and BBUThe BBU carrier plate can accommodate up to three BBUs. Figure 52: Position of used h

Strona 103 - Figure 77: Attaching labels

TX300 S6 Options Guide 81Expansion cards and BBU Installing a BBUFigure 53: Fastening BBUs onto the BBU carrier plateÊ Fasten each BBU onto the BBU ca

Strona 104

82 Options Guide TX300 S6Installing a BBU Expansion cards and BBUFigure 54: Connecting the cable to the BBUÊ Connect the BBU cables to the BBUs.V CAUT

Strona 105 - V CAUTION!

TX300 S6 Options Guide 83Expansion cards and BBU Installing a BBUFigure 55: Inserting the BBU carrier plateÊ Insert the BBU carrier plate in the reces

Strona 106 - 106 Options Guide TX300 S6

84 Options Guide TX300 S6Installing a BBU Expansion cards and BBUFigure 56: Fastening the BBU carrier plateÊ Close the BBU carrier plate at the top on

Strona 107 - 11.2 Floorstand model

TX300 S6 Options Guide 85Expansion cards and BBU Installing a BBUFigure 57: Opening the cable coverÊ Loosen the knurled screw on the cable cover (1) a

Strona 108

86 Options Guide TX300 S6Installing a BBU Expansion cards and BBUFigure 59: Routing the first and second BBU cableÊ Route the first and the second BBU

Strona 109 - TX300 S6 Options Guide 109

TX300 S6 Options Guide 87Expansion cards and BBU Installing a BBUFigure 60: Removing the voltage converter holderTo route the third BBU cable, the vol

Strona 110 - 11.2.3 Closing the server

88 Options Guide TX300 S6Installing a BBU Expansion cards and BBUFigure 61: Threading the third BBU cable through the cable openingÊ Thread the third

Strona 111

TX300 S6 Options Guide 89Expansion cards and BBU Installing a BBUFigure 62: Reinserting the voltage converter holderÊ Reinsert the voltage converter h

Strona 112

TX300 S6 Options GuideContents11 Completion . . . . . . . . . . . . . . . . . . . . . . . . . . . 10511.1 Installing the fa

Strona 113 - TX300 S6 Options Guide 113

90 Options Guide TX300 S6Installing a BBU Expansion cards and BBUFigure 63: Securing the voltage converter holderÊ Secure the voltage converter holder

Strona 114 - Rack model Completion

TX300 S6 Options Guide 91Expansion cards and BBU Installing a BBUFigure 64: Inserting and fastening the cable coverÊ Insert the cable cover in the rec

Strona 115 - 12 Appendix

92 Options Guide TX300 S6Installing a BBU Expansion cards and BBU

Strona 116 - Cabling Appendix

TX300 S6 Options Guide 939 Further optionsV CAUTION!Follow the safety instructions in the chapter "Safety instructions" on page 19.9.1 TPMT

Strona 117 - Appendix Cabling

94 Options Guide TX300 S6TPM Further optionsFigure 66: Inserting the TPM spacer on the system boardÊ Insert the TPM spacer into the hole on the system

Strona 118 - 118 Options Guide TX300 S6

TX300 S6 Options Guide 95Further options TPMFigure 67: Securing the TPMÊ Insert the TPM on the system board (1).Ê Fasten the TPM with the special scre

Strona 119 - Options Guide 119

96 Options Guide TX300 S6USB Flash Module (UFM) Further options9.2 USB Flash Module (UFM)The server can be equipped with a USB Flash Module (UFM).Figu

Strona 120 - 120 Options Guide TX300 S6

TX300 S6 Options Guide 97Further options USB Flash Module (UFM)Figure 70: Connecting the UFM to the system boardÊ Connect the USB Flash Module to the

Strona 121 - TX300 S6 Options Guide 121

98 Options Guide TX300 S6USB Flash Module (UFM) Further options

Strona 122

TX300 S6 Options Guide 9910 Conversion from a floorstand model to a rack modelV CAUTION!Follow the safety instructions in the chapter "Safety in