Fujitsu INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 Instrukcja Użytkownika Strona 368

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 426
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 367
368 iRMC S2/S3
Flash tools
10.5 Flash tools
I The tools WinFLIRMCS2, rFLIRMCS2 and sFLIRMCS2 differ from
flirmcs2 only in respect of the name and the environment in which they
are called. This means that the description below also applies to
WinFLIRMCS2, rFLIRMCS2 and sFLIRMCS2. Instead of “flirmcs2”, you
simply enter “WinFLRMCS2”, “rFLIRMCS2” or “sFLIRMCS2” as
appropriate.
Syntax
flirmcs2 {/v|/o [/4]|/s[<value>]}
flirmcs2 {<file1> [<file2>] [<file3>]
[/n /l[<logfile>] /d /e /4 /i]}
flirmcs2 {/h|/?}
Options
/v Displays the current version of the command.
/o Displays the current versions of both firmware images.
/s Displays the value of the firmware selector.
/s <value>
Sets the value of the firmware selector. You use this option to define the
firmware image from which the firmware is started after a firmware reset.
0 Sets the selector to the firmware image with the most recent
firmware.
1 Sets the selector to firmware image 1.
2 Sets the selector to firmware image 2.
3 Sets the selector to the firmware image with the oldest firmware.
4 Sets the selector to the firmware image with the most recently
updated firmware.
5 Sets the selector to the firmware image with the firmware which
has not been updated for longest.
Przeglądanie stron 367
1 2 ... 363 364 365 366 367 368 369 370 371 372 373 ... 425 426

Komentarze do niniejszej Instrukcji

Brak uwag