Fujitsu PCI Gigabit Ethernet 4.1 Update 2/ 5.0 for Oracle Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Fujitsu PCI Gigabit Ethernet 4.1 Update 2/ 5.0 for Oracle . FUJITSU PCI Gigabit Ethernet 4.1 Update 2/ 5.0 for Oracle Solaris C120-E276-11ENZ0(A) User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - User's Guide

C120-E276-11ENZ0(A)October 2011SolarisFUJITSU PCI Gigabit Ethernet4.1 Update2 / 5.0for Oracle SolarisUser's GuideSPARC Enterprise

Strona 2

Figure 1.1 1000Base-SX * 2ports (SE0X7GD2X)Figure 1.2 10/100/1000Base-T * 2ports (SE0X7GD1X)- 4 -

Strona 3 - Revision History

Figure 1.3 10/100/1000Base-T * 4ports (SE0X7GQ1X)Figure 1.4 10/100/1000Base-T * 4ports (SE0X7GQ2X)- 5 -

Strona 4

Chapter 2 Gigabit Ethernet Card InstallationThis chapter describes the tasks necessary to install this card in your system.Install the hardware with t

Strona 5 - Contents

Figure 2.1 SE0X7GD2X (with Multimode Optical Fiber Cable)- 7 -

Strona 6

Figure 2.2 SE0X7GD1X (with Twisted Pair CAT5e Cable)- 8 -

Strona 7 - Chapter 1 Product Outline

Figure 2.3 SE0X7GQ1X (with Twisted Pair CAT5e Cable)- 9 -

Strona 8 - 1.2.1 Specifications

Figure 2.4 SE0X7GQ2X (with Twisted Pair CAT5e Cable)- 10 -

Strona 9

Chapter 3 Setting InstructionsThis chapter describes the summary of environment settings required after installing this product.Install the driver and

Strona 10

3.3 Environment SettingThis section explains how to edit the necessary files and use the commands(Solari 11 only) to configure the operating environme

Strona 11

3. Edit the /etc/inet/netmasks fileDescribe the relationship between the network address and the netmask in the /etc/inet/netmasks file.Example of the

Strona 12 - 2.3 Cable Connection

Preface PurposeThis manual describes how to install the Gigabit Ethernet card into your SPARC Enterprise system, and configure the environmentalsettin

Strona 13

3.3.2 Environment Setting of IPv6 Interfaces- Solaris 10 8/07 or later1. Edit the /etc/hostname6.fjgi* fileAssign an IPv6 address or hostname and pre

Strona 14

Information- The following example shows how to display an IP address and prefix length that assigned the fjgi interface.Example:When setting an IP a

Strona 15

FJSV,e2ta, instance #6 (driver name: fjgi)FJSV,e2ta, instance #7 (driver name: fjgi)FJSV,e4tb, instance #8 (driver name: fjgi)FJSV,e4tb, instance #9 (

Strona 16

Logical bus address Instance number Driver name"/pci@1,700000/pci@0,1/FJSV,e4ta@6,1" 3 fjgi"/pci@3,700000/pci@0/FJSV,e2sa@4" 4 fjg

Strona 17

Parameter Value DescriptionLinkSpeed_A (*1)Auto (default)Any connection speed of 1000, 100, or 10Mbps is set based on negotiation with theremote devic

Strona 18 - 3.3 Environment Setting

Parameter Value DescriptionTransmitMaxBD1 to 500 (*3)(default: 128)The number of buffer descriptor to waitfor an interrupt for transmitting isspecifie

Strona 19 - Information

The parameter values need to be set by character strings like AutoNegotiation_A="On", LinkSpeed_A="100" andDuplexCapabilities_A=&q

Strona 20

The parameter value needs to be set by a character string like fjgi0=":::8000::::::".The following is added to the fjgi.conf file:fjgi0=&quo

Strona 21

Parameter Value DescriptionRemOnly flow control from the remote deviceis allowed. Flow control from the localdevice is not allowed.LocSendOnly flow co

Strona 22

- From the above example, instance number and driver name for each interface can be determined. Device node of device tree Instance number Driver name

Strona 23 - 3.5 Operation Mode Setup

Note- This symbol indicates that important information is given. Information- This symbol indicates that useful information is given. Handling of Th

Strona 24

SE0X7GD1Xname fjgiparent /pci@3,700000/pci@0unit-addressinstance 6 is 4instance 7 is 4,1 SE0X7GQ2Xname fjgiparent /pci@4,600000/pci@0 /pci@4,600000/p

Strona 25 - LinkSpeed_A="100"

Example 4: The parameters for all instances are set to "Auto-Negotiation is disabled", "Connect at 100Mbps" and "Half-Duplexo

Strona 26

- When "Method 1: Setting method of new style" and "Method 2: Setting method of old style" are specified at the same time, the dri

Strona 27

fjgi0=":::8000::::::";2. Reboot the system.- Setting method of old style1. Add the fjgi_mtu parameter to the fjgi.conf file. The parameter v

Strona 28 - [Parameter Setting]

3.5.3 Using the ndd(1M) commandBy using the ndd(1M) command, the interface communication mode can be changed dynamically. Usually it is not necessary

Strona 29

# ndd -set /dev/fjgi0 adv_1000fdx_cap 0# ndd -set /dev/fjgi0 adv_1000hdx_cap 0# ndd -set /dev/fjgi0 adv_autoneg_cap 0# ndd -set /dev/fjgi0 adv_autoneg

Strona 30

Parameter Status Meaningadv_10fdx_cap Read and write10Mbps/FullDuplex Setting0: Disabled1: Enabled (default)adv_10hdx_cap Read and write10Mbps/HalfDup

Strona 31

Parameter Status Meaninglp_pauseTX Read onlySet link-partner to transmit pause frame by Auto-Negotiation.0: Disabled1: Enabledlp_pauseRX Read onlySet

Strona 32 - 3.5.2 JumboFrame Setup

- The values of lp_10fdx_cap, lp_10hdx_cap, lp_100fdx_cap, lp_100hdx_cap, lp_1000fdx_cap, lp_1000hdx_cap, lp_pauseTX,lp_pauseRX, and lp_autoneg_cap pa

Strona 33

Propertiy Status Meaningadv_autoneg_cap Read and writeAuto-Negotiation Setting0: Auto-Negotiation Off (Forced mode)1: Auto-Negotiation On (default)mtu

Strona 34

Edition Date DetailsSupport switches was addedChanged the Version 2.1 to 2.205 2005-11-11Quad Gigabit Ethernet card(PW008QG1) was supportedChanged the

Strona 35

Propertiy Status Meaning_cardtype (*2) Read only0: SX (SE0X7GD2X)1: T (SE0X7GD1X/SE0X7GQ1X/SE0X7GQ2X)_Role_A (*2) Read and writeRole setting when oper

Strona 36

3.5.5 FCode SettingsFCode settings must be changed when the remote device does not support Auto-Negotiation and the communication by FCode is needed(

Strona 37

- Execute the following command to set Half Duplex communication, 10Mbps.ok transfer-speed=10ok half-duplex- Execute the following command to display

Strona 38

- How to Return to Default FCode Settings (Auto-Negotiation Mode):- To return to default FCode settings, execute the following command from the ok pr

Strona 39

The FUJITSU PCI GigabitEthernet 4.1 or later drivers support: Supported VIDs 1 - 4094Max number of VLAN interfaces 10243.7.2 Setting Up the VLAN Inte

Strona 40

- To create a VLAN Interface of VID=231 for fjgi3 (this vanity name is net5), the following is used.Refer to "3.3 Environment Setting", and

Strona 41 - 3.5.5 FCode Settings

Chapter 4 LinkAggregation FeatureThis chapter outlines the LinkAggregation feature, and explains the settings required to use this feature.- 4.1 About

Strona 42

- LAN switch that supports the LinkAggregation (or equivalent) feature - Data Distribution Mode"Table 4.2 Data Distribution Mode" shows data

Strona 43 - 3.7 VLAN Interface Setup

This mode is used for re-configuring the LinkAggregation Group of thepartner device automatically when the configuration of theLinkAggregation Group o

Strona 44

Note- For more information about the dladm(1M) command, please refer to the "System Administration Guide: IP Services" and the "manpag

Strona 45

ContentsChapter 1 Product Outline...

Strona 46

1. Create the LinkAggregation Group- Solaris 10 8/07 or laterThe following example shows how to create the LinkAggregation Group with the fjgi0, fjgi1

Strona 47

1. Describe the hostname in the /etc/hostname.aggr1 file.Example (Hostname is giga-lacp.):# cat /etc/hostname.aggr1giga-lacp2. Define the relation bet

Strona 48

1. Define the relation between the IP address and the hostname in the /etc/inet/hosts file.Example (Hostname is giga-lacp and its IP address is 192.16

Strona 49

4.2.1.2 Delete a LinkAggregation (dladm delete-aggr)This section explains the dladm delete-aggr command for inactivating LinkAggregation. - Synopsis-

Strona 50

2. Delete the LinkAggregation Group- Solaris 10 8/07 or laterThe following example shows how to delete the "key=1" LinkAggregation Group (*3

Strona 51

passive: passive mode off: off mode -T time: Specify the LACP timer short: every one second long:

Strona 52

4.2.1.4 Add Interfaces to a LinkAggregation (dladm add-aggr)This section explains the dladm add-aggr command for adding interfaces to a LinkAggregati

Strona 53

- Solaris 10 8/07 or later- The following example shows how to add the interface "fjgi3" to the "key=1" LinkAggregation Group:# /u

Strona 54

- Synopsis- Solaris 10 8/07 or later/usr/sbin/dladm remove-aggr -d dev [-d dev] ... key -d dev: Specify the name of the physical interface (includi

Strona 55

- Solaris 10 8/07 or later- The following example shows how to remove the interface "fjgi2" from the "key=1" LinkAggregation Group

Strona 56

D.3 Notes...

Strona 57

- Synopsis- Solaris 10 8/07 or later/usr/sbin/dladm show-aggr [-s [-i interval]] [-L] [key] -s: Specify to display the statistics. -i interval:

Strona 58

- The following example shows how to display the detailed LinkAggregation Information for the "key=1" LinkAggregation Group:# /usr/sbin/dlad

Strona 59

aggr1 net3 124 16.03K 147 18.82K aggr1 net4 122 15.62K 148 18.94K*: net2, net3, a

Strona 60

Chapter 5 TroubleshootingThe following should be checked first to troubleshoot a problem. Is the driver software installed correctly?If the "pkgi

Strona 61

Appendix A MessagesThis chapter explains messages displayed by the FUJITSU PCI GigabitEthernet driver.A.1 Console Messages from the DriverMessages f

Strona 62 - 4.3 Notes

No Message Cause Workaround15 DETACH failed ([detail]) Unloading of the driver failed.After disabling the driver, re-do theprocess (disconnect in Dyna

Strona 63 - Chapter 5 Troubleshooting

No Message Cause WorkaroundMaster: Communicating asMasterSlave: Communicating as Slave3 Illegal value for [ParameterName]An error was found with apara

Strona 64 - Appendix A Messages

Table A.4 Messages Reported by Machine AdministrationNo Message Meaning Workaround1 fjgi_device_check: fjgi_hw_deinit failed !An error occurred durin

Strona 65

Appendix B Gigabit Ethernet Card LED DiagnosisThis appendix explains the LED diagnosis function of Gigabit Ethernet cards.B.1 Location and Meaning o

Strona 66

Figure B.2 10/100/1000Base-T * 2ports (SE0X7GD1X) - Meaning of the LEDs (SE0X7GD1X)The following tables show the meaning of each LED.1000M LED indicat

Strona 67

Chapter 1 Product OutlineThis chapter describes the following topics.- 1.1 Key Features- 1.2 Gigabit Ethernet Card Specifications1.1 Key FeaturesThe G

Strona 68

Figure B.3 10/100/1000Base-T * 4ports (SE0X7GQ1X)Figure B.4 10/100/1000Base-T * 4ports (SE0X7GQ2X) - Meaning of the LEDs (SE0X7GQ1X/SE0X7GQ2X)The foll

Strona 69

ACT LED DescriptionON (Green) The card is transmitting or receiving network data.OFF The card is not transmitting or receiving network data.- 65 -

Strona 70

Appendix C Using FUJITSU PCI GigabitEthernet in aCluster EnvironmentThis Appendix outlines the supported functions and setup procedure for the FUJITS

Strona 71 - ACT LED Description

Appendix D Using FUJITSU PCI GigabitEthernet in SolarisContainersThis Appendix outlines the supported functions and setup procedure for the FUJITSU P

Strona 72 - Cluster Environment

zonecfg:zonename> add net (Begin adding network.)zonecfg:zonename:net> set address=IP-address/prefixlen (Specify IP

Strona 73 - Containers

(Note 1) In Solaris 11, the vanity name (net4) is specified as fjgi2. (Note 2) Reboot the Exclusive-IP Non-Global Zone to make this setting effecti

Strona 74

zonecfg:zone1:net> set physical=net1002zonecfg:zone1:net> endzonecfg:zone1> exit (Note 1) zonecfg create -b command must be executed to crea

Strona 75 - D.3 Notes

- When a VLAN interface is used in Exclusive-IP Non-Global Zones, please add a VLAN interface of the fjgi interface to the Exclusive-IP Non-Global Zon

Strona 76 - - Solaris 11

1. Execute the following commands in the Global Zone.# /usr/sbin/dladm create-aggr -d fjgi0 -d fjgi1 -d fjgi2 2# zonecfg -z zone2zonecfg:zone2> set

Strona 77

Appendix E Using FUJITSU PCI GigabitEthernet in OracleVM Server for SPARCThis Appendix outlines the supported functions and setup procedure for the F

Strona 78

The GLDv3 compliant driver works with the following features.- The LinkAggregation (based on IEEE 802.3) by the dladm(1M) command.- Solaris Containers

Strona 79 - VM Server for SPARC

- The following example shows how to add a virtual switch (vsw) device (ldm add-vsw)/opt/SUNWldm/bin/ldm add-vsw net-dev=device vswitch_name ldom (dev

Strona 80

# /opt/SUNWldm/bin/ldm list-domain -l ldg1NAME STATE FLAGS CONS VCPU MEMORY UTIL UPTIMEldg1 active -n--- 5000

Strona 81 - E.3 Notes

Appendix F Using FUJITSU PCI GigabitEthernet in Solaris11 Network VirtualizationThis Appendix outlines the supported functions and setup procedure fo

Strona 82 - 11 Network Virtualization

Example: Creating VNICs (vnic2_1 and vnic2_2) over fjgi0 (this vanity name is net2).# dladm create-vnic -l net2 vnic2_1# dladm create-vnic -l net2 vni

Strona 83

# flowadm show-flowFLOW LINK IPADDR PROTO LPORT RPORT DSFLDvnic2_1_flow vnic2_1 -- tcp

Strona 84 - F.3 Notes

Appendix G PCI Slot Number and Device NameThis appendix provides a cross-reference of PCI slot numbers and device names for the following SPARC Enter

Strona 85

Board Number Slot Number Device NamePCI#1-PCIE6 /pci@0,600000/pci@0/pci@9/pci@0/pci@9/pci@0/pci@9/****@0Basic PCISlotPCI#2 /pci@1,700000/****@0PCI#2IO

Strona 86

Board Number Slot Number Device NamePCI#4-PCIE4 /pci@3,700000/pci@0/pci@9/pci@0/pci@0/****@0PCI#4-PCIE5 /pci@3,700000/pci@0/pci@9/pci@0/pci@1/****@0PC

Strona 87

Board Number Slot Number Device NamePCI#3IOBoat(Ex)PCI#3-PCIE1/pci@12,600000/pci@0/pci@1/pci@0/pci@0/****@0PCI#3-PCIE2 /pci@12,600000/pci@0/pci@1/pci@

Strona 88

Board Number Slot Number Device NameBasic PCISlotPCI#2 /pci@2,600000/****@0Basic PCISlotPCI#3 /pci@3,700000/****@0PCI#3IOBoat(X)PCI#3-PCIX1/pci@3,7000

Strona 89

Item Hardware SpecificationPower RequirementsMaximum: 9.1W (SE0X7GD1X), 9.2W (SE0X7GD2X),15.0W (SE0X7GQ1X), 12.8W (SE0X7GQ2X)Connections1000Base-SX (S

Strona 90

Board Number Slot Number Device NamePCI#7-PCIX4 /pci@7,700000/pci@0/pci@9/pci@0,1/****@4PCI#7IOBoat(Ex)PCI#7-PCIE1/pci@7,700000/pci@0/pci@1/pci@0/pci@

Strona 91

Board Number Slot Number Device NameBasic PCISlotPCI#5 /pci@15,700000/****@0PCI#5IOBoat(X)PCI#5-PCIX1/pci@15,700000/pci@0/pci@1/pci@0/****@4PCI#5-PCIX

Strona 92

- SPARC Enterprise T5120 Slot Number Device NamePCI-E#1 /pci@0/pci@0/pci@8/pci@0/pci@1/xxxxxxx@0PCI-E#0 /pci@0/pci@0/pci@8/pci@0/pci@9/xxxxxxx@0PCI-E

Strona 93

- SPARC Enterprise T5440 (2CPU) Slot Number Device NamePCI-E#3 /pci@400/pci@0/pci@8/pci@0/pci@9PCI-E#4 /pci@400/pci@0/pci@8/pci@0/pci@cPCI-E#1 /pci@4

Komentarze do niniejszej Instrukcji

Brak uwag