Fujitsu ServerView Respurce Orchestrator Virtual Edition V Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Komputery Fujitsu ServerView Respurce Orchestrator Virtual Edition V. FUJITSU ServerView Respurce Orchestrator Virtual Edition V3.1.0 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 247
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - User's Guide

J2X1-7606-05ENZ0(01)January 2013Windows/LinuxServerView Resource Orchestrator Virtual Edition V3.1.1User's Guide

Strona 2

Abbreviation ProductsROR ServerView Resource OrchestratorROR VE ServerView Resource Orchestrator Virtual EditionROR CE ServerView Resource Orchestrato

Strona 3 - Notational Conventions

Chapter 10 Configuring the Operating Environments ofManaged ServersThis chapter explains how to install software to the registered managed servers and

Strona 4

1. In the ROR console server resource tree, right-click the target physical server, and select [Modify]-[WWN Settings] from the popupmenu.The [WWN Set

Strona 5 - Abbreviations

- If the target CA is not displayed, confirm the status of the following settings:- ESC is correctly registered on Resource Orchestrator.- Fibre Chann

Strona 6

Chapter 11 Deleting ResourcesThis chapter explains how to delete resources.It is possible to register and delete a managed server and LAN switch as a

Strona 7

Information- If HBA address rename has already been set up on the managed server, the HBA WWN is reset to the factory default.When this occurs, the

Strona 8

- Server blades that are managed using VIOM, and are currently the target of operations by Resource Orchestrator (power control,image-related processe

Strona 9

11.6.1 Deleting Power Monitoring DevicesThis section explains how to delete power monitoring devices.Use the following procedure to delete power monit

Strona 10

Chapter 12 Pre-configuration for Resource Registrationand ModificationThis chapter provides an overview of the pre-configuration function and explains

Strona 11

- When saving a file in CSV format from the system configuration template, or exporting a system configuration file from the RORconsoleExport will be

Strona 12 - Contents

Note- The following operations cannot be performed by the pre-configuration function, and should be performed from the ROR console.- Deleting registe

Strona 13

Month/Year Issued,EditionManual CodeNovember 2011, FirstEditionJ2X1-7606-01ENZ0(00)December 2011, 1.1 J2X1-7606-01ENZ0(01)December 2011, 1.2 J2X1-7606

Strona 14

3. In the ROR console, select [File]-[System Configuration File]-[Import] from the menu.The [Import System Configuration File] dialog is displayed.4.

Strona 15

- When changing physical server names during pre-configuration, it cannot be performed at the same time as other pre-configuration operations. Import

Strona 16 - Chapter 1 Login and Logout

- If the agent is registered, perform either one of the following to enable further backup or cloning operations.- Restart the managed server.- Restar

Strona 17

Chapter 13 Network MapThis chapter provides an overview of the Network Map and describes its features.13.1 OverviewThe Network Map displays the follow

Strona 18

The following actions are available in the Network Map.- Switching between map types- Screen scrolling- Scroll button- Map drag and drop- Navigation m

Strona 19 - Chapter 2 Home

2. Detect physical network linksa. From the ROR console menu, select [Tools]-[Topology]-[Detect physical links].The [Detect Physical Links] dialog is

Strona 20

Update buttonUpdate the network map to show the latest status.Display filter areaProvides checkboxes to select which information to display in the net

Strona 21

- When selecting a serverThe following items are displayed:- NICsIn addition, the following items will be displayed when the selected server is a VM h

Strona 22

Table 13.1 Chassis IconsIcon Status Meaningnormal No new errors or warnings were detected from the chassis.warningA warning was detected from the chas

Strona 23

Table 13.3 LAN Switch Blade IconsIcon Status Meaning (*1) (*2)normalNo new errors or warnings weredetected from the LAN switchblade. (*1) (*2)warnin

Strona 24

ContentsChapter 1 Login and Logout...

Strona 25 - Chapter 6 BladeViewer

Table 13.5 VM Guest IconsIcon Status Meaningnormal No new errors or warnings were detected from the VM guest.warningA warning was detected from the VM

Strona 26 - 6.2 Screen Layout

Table 13.7 LAN Switch IconsIcon Status Meaningnormal No new errors or warnings were detected from the LAN switch.warningA warning was detected from th

Strona 27 - 6.3.2 Chassis Panel

Icon MeaningServer (*1) (*2)LAN switch bladeVM hostVM guestVirtual switchLAN switchPort*1: When operating in IBP mode*2: When operating in VCS mode

Strona 28 - 6.3.3 Blade Panel

Table 13.10 Admin Server IconIcon Status MeaningAdmin server Indicates the server used as the admin server. Table 13.11 Map Navigation IconsIcon Meani

Strona 29

13.5.3 Aggregate Display of Network LinksWhen two resources are linked by two or more links, those links are represented as one aggregated link (pleas

Strona 30

13.6 Display FiltersThis section explains how to use display filters.Resource descriptionsThe display filter area includes the following filters (chec

Strona 31 - 6.3.3.2 VM Guest List

Chapter 14 Power ControlThis chapter explains how to remotely control the power state of managed resources.14.1 Server Power ControlThis section expla

Strona 32

[Windows]- Take caution regarding the following points when shutting down or rebooting a managed server running a Windows operating system.- If Window

Strona 33 - 6.4 Power Control

Chapter 15 Control of VM EnvironmentsThis chapter explains the Resource Orchestrator functions that are specific to VM guests and VM hosts.Some functi

Strona 34

15.2 VM Maintenance Mode of VM HostsThis section explains how to set and release VM maintenance mode on VM hosts.For details on VM maintenance mode, r

Strona 35 - 6.4.2 VM Guest

8.1 Changing Admin IP Addresses...

Strona 36 - 6.5 Status Panel Operations

15.3.2 Migrating to VM Home PositionMigrate VM guests back to their original VM hosts using the relationship information that was registered in advanc

Strona 37 - Contents of the Label List

15.4 External SoftwareThis section explains how to configure the settings required by Resource Orchestrator to interact with third party software. VM

Strona 38 - 6.5.3 Changing Passwords

Chapter 16 Backup and RestoreThis chapter explains how to use the backup and restore functions provided in Resource Orchestrator.16.1 OverviewThe back

Strona 39 - - General user

files).During restore, because the target VM host will be automatically set to VM maintenance mode, the VM host should be in a state thatallows VM mai

Strona 40

>Installation_folder\SVROR\Manager\bin\rcxadm server set -name physical server -attr bootagt=dos <RETURN>[Linux Manager] #/opt/FJSVrcvmr/bin

Strona 41

b. Set the following items as necessary:CommentsEnter a comment to identify the system image.A comment can be up to 128 characters long. Use of percen

Strona 42 - 7.3 When Using Blade Servers

16.3 RestoreThis section explains how to restore a system image backup.System images can also be restored using commands.Refer to "Chapter 4 Imag

Strona 43

b. Click <OK>.The target server is released from maintenance mode. NoteIf the target VM host is in a high-availability configuration, all VM gu

Strona 44

16.4 ViewingThis section explains how to browse and view existing system image backups.System images can also be listed using commands.Refer to "

Strona 45

Chapter 17 Cloning [Physical Servers]This chapter explains how to use the server cloning function.17.1 OverviewCloning is a function used to deploy a

Strona 46

11.7 Deleting Admin LAN Subnets...

Strona 47

- Cloning images can be collected with the following file systems. Note that LVM (Logical Volume Manager) partitions are notsupported.- NTFS- EXT3- EX

Strona 48

A cloning image can be collected only from a managed server on which an agent has been registered.For details on registering agents, refer to "Ch

Strona 49

The maximum number of image versions is three by default.This setting can be changed by following the instructions given in "8.4 Changing the Max

Strona 50

Table 17.2 Structure of the Definition FileFormat Parameter ValueKMS.cmd.remotescript.1.params.kmscheck(Mandatory)KMS host search type.Select one of t

Strona 51

.cmd.remotescript.1.params.ieproxy=proxy.activation.com:8080.cmd.remotescript.1.params.password=PASSWORDIf the Administrator password has been changed

Strona 52

3. Collect a cloning image.a. In the ROR console server resource tree, right-click the physical OS of the source server and select [Cloning]-[Collect]

Strona 53

a. In the ROR console server resource tree, right-click the source server (or its physical OS) and select [Maintenance Mode]-[Release] from the popup

Strona 54

- When using the Red Hat Enterprise Linux 6 ext4 file system, and one of the following conditions is met- In a SAN boot environment using HBA address

Strona 55

- When using local disks as system disks, and iSCSI storage as data disks, refer to the advisory notes described in "Table 8.1 SupportedStorage D

Strona 56

[Release from Maintenance Mode after deployment] checkboxEnable this option to automatically release the destination server from maintenance mode afte

Strona 57

18.3 Changing Server Switchover Settings...

Strona 58

d. Click <OK>.The cloning image deployment process starts.The process status can be checked in the Recent Operations area of the ROR console.Cli

Strona 59

- Microsoft Internet Explorer settings (RSS feeds subscription information, information stored by the Autocomplete function, savedpasswords)- Microsof

Strona 60

In the ROR console, select the [Image List] tab.A list of cloning images is displayed under the cloning image list.Use this list to manage the cloning

Strona 61 - - For SPARC M10-1/M10-4

- When Using LAN Redundancy [Linux]- The "NIC switching mode (Physical IP address takeover function)" of PRIMECLUSTER Global Link ServicesFi

Strona 62

[Windows]Installation_folder\Agent\etc\FJSVrcx.confInstallation_folder\Agent\etc\ipaddr.conf[Linux]/etc/FJSVrcx.conf/etc/opt/FJSVnrmp/lan/ipaddr.confS

Strona 63

Table 17.3 Node Entry SettingsSetting Keyword Expected Values: DescriptionManaged servernameNODE_NAMEPhysical servernamePhysical server name that was

Strona 64

When there is a mixture of interfaces with and without redundancy, assign values in ascending order to the interfaces withoutredundancy as well.Interf

Strona 65

2. Enable the Network Parameter Auto-Configuration FunctionEnable the network parameter auto-configuration function by executing the following command

Strona 66

Items to confirm- The status of the virtual interface must be "Active".- When the standby patrol function is used ("p" mode), the

Strona 67

[Linux]/var/opt/FJSVnrmp/logs/error_lan.logFor details on meanings of message and the appropriate corrective actions, refer to "Messages".Th

Strona 68 - Drive_name

Chapter 1 Login and LogoutThis chapter describes how to open and close the ROR console. PreparationsBefore opening the ROR console, be sure to read th

Strona 69

Deploying New Managed Servers with Automated Public LAN ConfigurationUse the following procedure to add new managed servers and automate their public

Strona 70

Chapter 18 Server Switchover SettingsThis chapter explains how to use server switchover settings and automatically recover from server failures.18.1 S

Strona 71

Servers that have agents registered can be used as spare servers. When using a server on which an agent is registered as a spareserver, the server mus

Strona 72 - IP_address

[Power off forced when the server is switched over] checkboxCheck this checkbox if the spare server is to be turned off forcibly when the spare server

Strona 73

with Resource Orchestrator.The testing method for automatic server recovery is the same as for manual server switchover. Make sure the server is opera

Strona 74

ADMIN_IP=failover_admin_ipzfs_storage_pool[,zone_name,zone_name2]- Blank spaces before and after commas (",") are ignored.- When adding comm

Strona 75

1. In the ROR console server resource tree, right-click a server (or a physical OS or VM host on the server) and select [Modify]-[SpareServer Settings

Strona 76 - 8.2 Changing Port Numbers

Chapter 19 Collecting Power Consumption Data andDisplaying GraphsThis chapter explains how to export the power consumption data collected from registe

Strona 77

Target ResourcesSpecify the power monitoring target to export the power consumption data of.Select the checkboxes of each desired target. More than on

Strona 78

Rate Output time span Output device countDaily Last year 30Monthly Select "Custom" and specify 5 years 60Annual Select "Custom" an

Strona 79

URL: https://Admin_server_IP_address:23461/On a Windows admin server, the ROR console can also be opened by selecting [start]-[All Programs]-[Resource

Strona 80

Target ResourcesSpecify the power monitoring target name to display the power consumption data graph of.Select the checkboxes of each desired target.U

Strona 81 - Database

3. Click <Graph Output>.After switching to the graph display window, the selected power consumption data can be displayed in line graphs.Figure

Strona 82

Appendix A User InterfaceResource Orchestrator includes two graphical user interfaces: the ROR console and BladeViewer.This appendix provides an over

Strona 83 - Chapter 9 Changing Resources

- Physical OS- VM Host- VM Guest- LAN Switch (LAN Switch Blades)Network DevicesThe resources below are shown in a tree view. A status icon is displaye

Strona 84

- [Recovery Settings] TabDisplays information on the spare servers assigned to the resource selected in the resource tree.- [Image List] TabDisplays s

Strona 85

Menu SubmenuPrivilegedUserGeneral User FunctionView Reset Layout - Yes YesReturns the layout of the ROR consoleto its initial state.SettingsRegisterCh

Strona 86

Menu SubmenuPrivilegedUserGeneral User FunctionAdmin LAN Subnet - Yes Yes (*8)Performs viewing, registration,changing or deletion of the admin LANsubn

Strona 87 - 9.1.6 Changing Port Numbers

Menu SubmenuPrivilegedUserGeneral User FunctionOptions - Yes Yes (*11)Modifies client and environmental datasettings.Environmental DataGraph- Yes Yes

Strona 88 - 9.1.10 Changing Boot Options

* Note: This option is only available for chassis equipped with power monitoring capabilities. Table A.4 Popup Menus Available for ServersPopup MenuFu

Strona 89

Table A.5 Popup Menus Available for SPARC Servers/SPARC EnterprisePopup MenuFunctionMenu SubmenuRegisterServer (*1) Registers a server.Agent Register

Strona 90

Note- If the Web browser is closed without logging out first, user authentication may be skipped the next time Resource Orchestrator isaccessed. In t

Strona 91

Popup MenuFunctionMenu SubmenuRebootReboots a server after shutting down its operatingsystem.Reboot (Forced)Reboots a server without shutting down its

Strona 92

Popup MenuFunctionMenu SubmenuPowerONPowers on an operating system.OFFPowers off a server after shutting down its operatingsystem.OFF (Forced)Powers o

Strona 93

Popup MenuFunctionMenu SubmenuDelete - Deletes a cloning image. NoteIf ServerView Deployment Manager is used on the admin LAN, the popup menu for clo

Strona 94

Table A.15 Popup Menus Available for Management Software (vCenter Server/SCVMM/VIOM)Popup MenuFunctionMenu SubmenuDelete - Deletes management softwar

Strona 95

Figure A.4 Tree PanelIn the tree panel, clicking the area on the upper-left enables selection and display of the following 5 types of tree: server res

Strona 96

InformationFor a VM host coordinated with VMware vCenter Server, the name (IP address or host name) entered when registering with VMwarevCenter Serve

Strona 97 - 9.8 Changing Storage

Storage Location of the Definition File[Windows Manager]Installation_folder\SVROR\Manager\etc\customize_data[Linux Manager]/etc/opt/FJSVrcvmr/customiz

Strona 98

Network ResourcesInformation on all registered network resources is displayed.Power Monitoring DevicesInformation on all registered power monitoring d

Strona 99

Figure A.5 ChassisThe resource images shown in the above chassis image are explained in the table below. Table A.19 Meaning of the Resources Shown in

Strona 100 - Managed Servers

SeeRefer to "11.2 Resource Status" in the "Operation Guide VE" for details on resource statuses.Hardware Details AreaLaunch Mana

Strona 101

Chapter 2 HomeThis chapter explains the ROR Console Home window.When the ROR Console is started, the Home window is displayed. Refer to "Chapter

Strona 102 - 10.2 Deploying Cloning Images

A.6.2 Server AttributesGeneral AreaPhysical server nameThe name used to identify a server is displayed.Model nameThe model name of the server is disp

Strona 103 - Chapter 11 Deleting Resources

- SPARC Enterprise M-Series- SPARC M10Memory SizeThe total capacity of server memory is displayed.When using servers other than the following, a hyphe

Strona 104 - Information

Network Properties AreaPhysical ConnectionsThe list of physical connections between the server's network interfaces and LAN switch ports is displ

Strona 105 - 11.4 Deleting LAN Switches

A.6.3 Physical OS, VM Host, and VM Guest AttributesGeneral AreaServer nameThe name used to identify a physical OS, VM host, or VM guest is displayed.

Strona 106

VM Home Positions (VM Guests)A list of the VM guests with the selected VM host set as their VM Home Position is displayed.VM Guest Information AreaThe

Strona 107 - 12.1 Overview

Server switchover methodThe method used to perform server switchover is displayed.Server boot methodThe boot type of the system disk is displayed.Auto

Strona 108

GroupThe names of the port groups set on the LAN switch ports connected to each network interface (for LAN switch blades operatingin IBP mode) are dis

Strona 109

A.6.4 Network Device AttributesGeneral AreaNetwork device nameThe name used to identify a network device is displayed.System Name (sysName)The name o

Strona 110

Member PortWhen the name of a port with link aggregation is displayed for the port name, the port names of the physical port with linkaggregation are

Strona 111

- PY CB Eth Switch/IBP 1Gb 36/12- PY CB Eth Switch/IBP 1Gb 18/6Network linksThe following information is only displayed for LAN switch blades.Resource

Strona 112

Preface Resource Orchestrator Documentation Road MapThe documentation road map for Resource Orchestrator is as shown below.Resource Orchestrator Docum

Strona 113 - Chapter 13 Network Map

c. Set the following items:ScheduleThere is no specified format.When not displaying the date, leave this field blank.Enter up to 30 alphanumeric chara

Strona 114 - 13.2 Preparations

Firmware versionThe firmware version of the device (PDU or UPS) is displayed.Date of manufactureThe date of manufacture of the PDU or UPS is displayed

Strona 115 - 13.3 Screen Layout

Switchover StateThe current switchover state is displayed.Spare ServerThe configured spare server is displayed.The switchover state is indicated by an

Strona 116 - 13.3.2 Map Types

A.9 Network MapResource Orchestrator displays the following information.- Network configuration of physical and virtual servers (including virtual sw

Strona 117 - 13.4 Resource Icons

When the link in the [Operation] column is clicked, the [Progress Details] dialog is displayed.The [Progress Details] dialog displays the following in

Strona 118 - Table 13.2 Server Icons

Event LogContent of the event.When the link in the [Event Log] column is clicked, an error dialog is displayed. The error dialog provides detailed inf

Strona 119 - Table 13.4 VM Host Icons

<Deselect All> buttonDeselects all dialog checkboxes.3. Click <Apply>.The new settings are applied.- 190 -

Strona 120 - Table 13.5 VM Guest Icons

Appendix B Format of CSV System Configuration FilesThis appendix explains the format of the CSV system configuration files used by Resource Orchestra

Strona 121 - 13.4.2 VLAN Display

- From the ROR consoleThe System Configuration Template can be obtained from a Resource Orchestrator manager installation.1. Open and log in to the RO

Strona 122 - 13.4.3 Other Icons

- RCXCSV V3.2 and Later"PRIMERGYPartitionModelChassis", "PRIMERGYPartitionModelServer"- RCXCSV V3.3 and Later"Subnet", &

Strona 123 - 13.5 Network Links

- changeModification- Hyphens, ("-")Do nothing- ParameterThis describes the parameter value to be set. NoteThe order of operation and param

Strona 124 - Example

Chapter 3 Resource Management OverviewThis chapter provides an overview of the two views available on the [Resource] tab in Resource Orchestrator.Reso

Strona 125 - 13.6 Display Filters

Order Section Name3 Chassis4 PRIMERGYPartitionModelChassis5 SPARCEnterprisePartitionModelChassis6 SPARCM10PartitionModelChassis7 LanSwitch8 LanSwitchN

Strona 126 - Chapter 14 Power Control

- As with chassis for server blades, and chassis for LAN switch blades, items that need to be registered in advance to enableregistration of other sho

Strona 127 - 14.2 Chassis Power Control

login_nameEnter the name of a VIOM user account.When specifying a domain, use the following syntax: "domain_name\user_name".login_passwdEnte

Strona 128

- Section HeaderoperationEnter the desired operation for the current line. Enter a hyphen ("-") to skip this line.chassis_nameEnter the name

Strona 129 - 15.3 VM Home Position

chassis_nameEnter the name that will be used to identify the chassis.Enter a character string beginning with an alphabetical character and containing

Strona 130

chassis_nameEnter the name that will be used to identify the chassis.Enter a character string beginning with an alphabetical character and containing

Strona 131 - 15.4 External Software

slot_noEnter the slot number where the LAN switch blade is installed. Enter a number between 1 and 8.switch_nameEnter the name to assign to this LAN s

Strona 132 - Chapter 16 Backup and Restore

product_nameEnter the model of the LAN switch blade. Note that if a hyphen ("-") is entered, it is treated as "BX600 GbE Switch Blade 3

Strona 133 - 16.2 Backup

Example10/U10/U;20/T;30/T10/T;20/T NoteIf a hyphen ("-") is entered, VLAN settings will not be performed.This section will be ignored for

Strona 134

ip_addressEnter the same IP address as that set within the server's operating system.Enter a string of numeric values (between 0 and 255) and per

Strona 135

Chapter 4 License Setup and ConfirmationThis chapter explains how to configure and confirm licenses. License SetupWhen using Resource Orchestrator, it

Strona 136 - 16.3 Restore

NoteIf the name of the current administrator account on the remote management controller is longer than 16 characters, either createa new account or

Strona 137

- When not using the NIC specified in the admin_lan2_nic_number as the backup for admin LAN redundancy"OFF" SPARC Enterprise M3000/T Series

Strona 138 - 16.5 Deleting

mgmt_passwdEnter the password of the remote management controller (ILOM/XSCF) to manage a server.- For XSCFEnter up to 32 characters, including alphan

Strona 139 - 17.1 Overview

- For XSCFEnter up to 31 characters, including alphanumeric characters, underscores ("_"), or hyphens ("-"). This name should star

Strona 140 - 17.2 Collecting

- When installing using a legacy boot"legacy"- When installing using UEFI"uefi" Server Blade VLAN Data- Section NameEnter [ServerN

Strona 141

SPARC Enterprise M4000/M5000/M8000/M9000 Server Management Data- Section NameEnter [SPARCEnterprisePartitionModelServer] as the section name.- Section

Strona 142

NoteServer names should be unique between all servers.Names are not case-sensitive.ip_addressEnter the same IP address as that set within the server&

Strona 143

spare_serverEnter the physical server name of a server to be assigned as a spare server.To specify multiple spare servers, separate each server name u

Strona 144 - Installation_folder

productEnter the name of this VM management software. Enter one of the following.- When using VMware vCenter Server as VM management software."vm

Strona 145

vm_login_nameEnter the name of the user account used to remotely log into the VM Host.vm_login_passwdEnter the password of the above user account (for

Strona 146 - 17.3 Deploying

Chapter 5 Managing User AccountsThis chapter explains how to register, modify, and delete user accounts. Add User AccountOnly privileged users can per

Strona 147

Power Monitoring Device Data- Section NameEnter [PowerDevice] as the section name.- Section HeaderoperationEnter the desired operation for the current

Strona 148

Memo- Section NameEnter [Memo] as the section name.This is required when registering the labels, comments, and contact information (displayed in Blade

Strona 149

RCXCSV,V3.5# ServerView Resource Orchestrator# System configuration file[Subnet]operation,subnet_name,network_address,subnet_mask,gateway-,subnet1,172

Strona 150

-,chassis01,2,36,1/U-,chassis01,2,37,1/U-,chassis01,2,38,1/U-,chassis01,2,39,1/U-,chassis01,2,40,1/U-,chassis01,2,41,1/U-,chassis01,2,42,1/U-,chassis0

Strona 151 - 17.4 Viewing

-,blade002,6,1/U-,blade003,2,1/U-,blade003,4,1/U-,blade003,6,1/U[SPARCEnterprisePartitionModelServer]operation,chassis_name,partition_no,server_name,i

Strona 152 - 17.5 Deleting

Appendix C Maintenance ModeThis appendix explains the maintenance mode available in Resource Orchestrator and how to use it.Maintenance mode is used

Strona 153

Glossary access pathA logical path configured to enable access to storage volumes from servers. active modeThe state where a managed server is perform

Strona 154

BACS (Broadcom Advanced Control Suite)An integrated GUI application (comprised from applications such as BASP) that creates teams from multiple NICs,

Strona 155

DR OptionThe option that provides the function for remote switchover of servers or storage in order to perform disaster recovery. end host modeThis i

Strona 156

hardware maintenance modeIn the maintenance mode of PRIMEQUEST servers, a state other than Hot System Maintenance. HBA (Host Bus Adapter)An adapter fo

Strona 157

New password (Confirm password)Enter a string using up to 16 alphanumeric characters or symbols.Authority LevelNo change/ChangeSelect the appropriate

Strona 158 - 17.6.2 Maintenance

iSCSIA standard for using the SCSI protocol over TCP/IP networks. LAN switch bladesA LAN switch that is mounted in the chassis of a blade server. lice

Strona 159 - 17.6.3 Clearing Settings

In regards to the network device file management function, these files are excluded from the scope of version management (They arenot automatically de

Strona 160

OSThe OS used by an operating server (a physical OS or VM guest). PDU (Power Distribution Unit)A device for distributing power (such as a power strip)

Strona 161 - 18.1 Status Display

public LANA LAN used for operations by managed servers.Public LANs are established separately from admin LANs. rackA case designed to accommodate equi

Strona 162

ROR consoleThe GUI that enables operation of all functions of Resource Orchestrator. SAN (Storage Area Network)A specialized network for connecting se

Strona 163

SNMP (Simple Network Management Protocol)A communications protocol to manage (monitor and control) the equipment that is attached to a network. softw

Strona 164

UPS (Uninterruptible Power Supply)A device containing rechargeable batteries that temporarily provides power to computers and peripheral devices in t

Strona 165

VM Home PositionThe VM host that is home to VM guests. VM hostA server on which server virtualization software is operated, or the server virtualizati

Strona 166 - 3. Click <OK>

Chapter 6 BladeViewerThis chapter provides an overview of BladeViewer and explains its features.Please note that BladeViewer is only available for PRI

Strona 167 - Displaying Graphs

- Display of contact informationBladeViewer allows users to define technical (support) contact information for their entire IT system. This contact in

Strona 168

6.3.1 Status PanelThe status panel displays a summary of resources statuses (including resources other than PRIMERGY BX servers).When a problem occur

Strona 169 - 2. Set the following items:

Table 6.4 Chassis IconIcon MeaningChassis SeeFor details on the different chassis statuses, refer to "Table 6.3 Status Icons" of "6.3.

Strona 170

Figure 6.3 Blade Panel: Resource List Server BladeA power button is displayed in the upper-part of each server blade.This power button is used to repr

Strona 171

Chapter 9 Changing ResourcesExplains how to change settings for the admin server or resources registered on the admin server.Chapter 10 Configuring th

Strona 172 - Appendix A User Interface

Table 6.8 Physical Server IconsIcon MeaningServerSpare serverUnregistered serverMaintenance mode server SeeFor details on the different physical serv

Strona 173

- If the OS name cannot be acquired (because the OS has not been installed or for other reasons)The server name (physical server name or VM guest name

Strona 174 - A.2 Menus

Figure 6.4 Blade Panel: VM Guest ListA VM guest icon is shown on the left side of each VM guest displayed in the VM guest list. Table 6.13 VM Guest Ic

Strona 175

Power button Color Status MeaningOrange (blinking)Power OFF inprogressPower OFF in progress. InformationThe power status of a VM guest can be easily

Strona 176

Power Off and RebootClicking on a power button that shows "Power ON" status will either shut down or reboot the target server blade. A [Powe

Strona 177 - A.2.2 Popup Menus

Figure 6.6 Power Operation Dialog (with Additional Options)- "Force Shutdown"Selecting "Force Shutdown" will forcibly power off th

Strona 178

Power button Color Status ActionGreen (lit) Power ON Shuts down or reboots a VM guest. Note- VM guests need to be properly configured in order to use

Strona 179

Contact iconDisplays the [Contact] dialog. This dialog shows the contact information that was set for the entire system.Tools iconEnables selection of

Strona 180

Editing Labels and CommentsThis function is only available to privileged users.General users are only able to consult labels and comments.- Privileged

Strona 181

- Privileged userNew password (Confirm password)Enter a string using up to 16 alphanumeric characters or symbols.- General userCurrent passwordEnter t

Strona 182

[Red Hat Enterprise Linux] Sections related to Red Hat Enterprise Linux[Solaris] Sections related to Solaris[VMware] Sections related to VMware[Hyper-

Strona 183 - A.4 Tree Panel

Chapter 7 Registering ResourcesThis chapter explains how to register, change, and delete resources used by Resource Orchestrator.The Resource Orchestr

Strona 184 - Figure A.4 Tree Panel

NoteHBA address rename and VIOM cannot be used together within the same chassis.When using backup and restore or cloning, prioritize the following t

Strona 185

PasswordEnter the password for VM management software.Enter up to 128 characters, including alphanumeric characters and symbols (ASCII characters 0x20

Strona 186 - A.5 [Resource List] Tab

SNMP CommunityEnter the SNMP community that was set on the chassis management blade.Select either "public" or enter an arbitrary string.Ente

Strona 187 - A.6 [Resource Details] Tab

Figure 7.1 Status Transition Diagram for Managed ServersUse the following procedure to register blade servers.1. In the ROR console server resource tr

Strona 188 - A.6.1 Chassis Attributes

Note- If ServerView Agents (mandatory software) is not running, message number 67231 will be displayed. In this case, serverregistration succeeds, bu

Strona 189

These settings can be changed after server registration.For details on how to modify these settings, refer to "9.1.10 Changing Boot Options"

Strona 190 - A.6.2 Server Attributes

3. Click <OK>.The registered server will be displayed in the server resource tree. Note- When an agent is registered on a VM host, all VM guest

Strona 191

Administrative passwordEnter the password of this LAN switch blade's telnet or SSH administrator account.If the user ID and the password of the a

Strona 192

NoteVLANs cannot be configured on PRIMERGY BX 900 and BX 400 LAN switch blades operating in IBP mode.7.3.5 Configuring VLANs on External PortsUse t

Strona 193 - - VM Guest

When using Windows 32-bit (x86)C:\Program Files\Resource Orchestrator AbbreviationsThe following abbreviations are used in this manual: Abbreviation P

Strona 194 - - PRIMEQUEST

Tagged VLANVLAN IDEnter the tagged VLAN ID(s) to assign to the LAN switch blade port that is connected to the network interface selected instep 2.Mult

Strona 195

Figure 7.2 Status Transition Diagram for Managed ServersUse the following procedure to register rack mount or tower servers.1. In the ROR console serv

Strona 196

- Admin LAN- IP address- MAC address (NIC1)- SAN Boot/Admin LAN Redundancy- MAC address (NIC2)Automatic registration of agents is not performed after

Strona 197

Association with server management software (ServerView)Enable/DisableFor PRIMERGY BX serversSelect [Enable] and enter an [SNMP Community].For servers

Strona 198

For a Physical OSSelect [Windows/Linux].For a VM HostSelect [VM Host], and enter the VM host login account information.This login account information

Strona 199

7.4.2 Registering LAN SwitchesUse the following procedure to register LAN switches:1. Discover LAN switches. For instructions, refer to "Discove

Strona 200 - A.7 [Recovery Settings] Tab

SNMP CommunityEnter the SNMP community that was set on this LAN switch.Either select [public] or enter an arbitrary string.Enter a string of up to 32

Strona 201 - A.8 [Image List] Tab

2. Define the following settings:WWNNSpecify the WWNN value provided by the "I/O virtualization Option".The admin server generates WWPNs aut

Strona 202 - A.10 Recent Operations

Figure 7.4 Procedures for Multi-path Configurations ExampleFor a server with two ports, WWNs could be configured as follows.WWNN value provided by &q

Strona 203 - A.11 Event

The server restart is not required in other cases. The WWN that has been set is enabled at the next restart.4. Click <OK>. InformationWhen usin

Strona 204 - A.12 Dialogs

Abbreviation ProductsWindows PE Microsoft(R) Windows(R) Preinstallation EnvironmentLinuxRed Hat(R) Enterprise Linux(R) AS (v.4 for x86)Red Hat(R) Ente

Strona 205 - 3. Click <Apply>

PasswordEnter the password of the above remote server management user account.This password must be between 8 and 16 alphanumeric characters long. No

Strona 206

Chassis nameEnter a name to assign to this chassis.Enter a character string beginning with an alphabetical character and containing up to 10 alphanume

Strona 207 - B.2 File Format

- For SPARC Enterprise M4000/M5000/M8000/M9000 or SPARC M10-4SRight-click the server in the chassis, and select as follows:Select [Register]-[Server]

Strona 208

IP addressEnter the IP address of this server's remote management controller (XSCF).User IDEnter the ID of a XSCF user account with administrativ

Strona 209

For a VM HostSelect [VM Host], and enter the VM host login account information.This login account information will be used by Resource Orchestrator to

Strona 210

Admin LAN (IP address)Enter the IP address that was set on this power monitoring device. This IP address will be used to collect power consumptiondata

Strona 211 - B.3 Resource Definitions

Subnet maskEnter valid values for the subnet mask.GatewayEnter the settings for the gateway used for communication with the admin server on the admin

Strona 212

Resources forDeletionRegistry Key[HKEY_LOCAL_MACHINE\]SOFTWARE\Wow6432Node\Fujitsu\SystemcastWizard\PXE\ClientBoot\- x86 Resources forDeletionRegistry

Strona 213

9. Configure access rights for the folder for the DHCP Server that was copied to the shared disk. Execute the following commandusing the command promp

Strona 214

Resource for Configuration Dependent ResourcePXE Services DHCP Server13. Restart the manager.Right-click [Services and Applications]-[RC-manager] on t

Strona 215

Abbreviation ProductsOracle Enterprise Linux Release 5 Update 4 for x86_64 (64 Bit)Oracle Enterprise Linux Release 5 Update 5 for x86 (32 Bit)Oracle E

Strona 216

Table 7.1 Files to LinkShared Disk Local DiskMount_destination_of_shared_disk/Fujitsu/ROR/SVROR/etc/dhcpd.conf (*1) /etc/dhcpd.confMount_destination_o

Strona 217

7.9 Registering ETERNUS SF Storage CruiserThis section explains how to register ETERNUS SF Storage Cruiser.Registering ETERNUS SF Storage Cruiser enab

Strona 218

Chapter 8 Changing Admin Server SettingsThis chapter explains how to change the settings for the admin server.8.1 Changing Admin IP AddressesUse the f

Strona 219

8. Stop the agents on managed servers. [Windows] [Hyper-V] [Linux] [Xen] [KVM]Stop the agent referring to "2.2 Starting and Stopping the Agent&qu

Strona 220

2. Log in to the admin server's primary node.Log in to the operating system of the admin server's primary node with administration privilege

Strona 221

b. Click <Add> on the [Registry Replication] tab.The [Registry Key] window will be displayed.c. Configure the above registry key in [Root regist

Strona 222

ExampleWhen the takeover logical IP address is 192.168.4.100 before being changed ## DHCP Server Configuration file.# see /usr/share/doc/dhcp*/dhcpd.

Strona 223

- Related Services- Deployment Service- TFTP Service- PXE Services- DHCP Server (*)[Linux Manager]- Manager Services- rcxmanager- rcxtaskmgr- rcxmongr

Strona 224

# /opt/FJSVrcvmr/bin/rcxadm mgrctl modify -port name=number <RETURN>In a clustered manager configuration, bring offline all cluster resources ex

Strona 225

c. From the menu, select [Edit]-[Modify].The [Edit DWORD Value] dialog is displayed.d. Select [Decimal] and click <OK>.This port value will defi

Strona 226

Abbreviation ProductsRed Hat(R) Enterprise Linux(R) 5.3 (for Intel64)Red Hat(R) Enterprise Linux(R) 5.4 (for x86)Red Hat(R) Enterprise Linux(R) 5.4 (f

Strona 227

8.4 Changing the Maximum Number of Cloning Image VersionsUse the following procedure to change the maximum number of cloning image versions.1. Change

Strona 228

a. In the [Failover Cluster Management] window, right-click the [Deployment Service] resource in [Summary of RC-manager]-[Other Resources], and select

Strona 229

1. Log on to the admin server with OS administrative privileges.2. Stop the manager.Stop the manager, referring to "2.1 Starting and Stopping the

Strona 230

Chapter 9 Changing ResourcesThis chapter explains how to change settings for the admin server or resources registered on the admin server.9.1 Changing

Strona 231 - B.4 Examples of CSV Format

4. If the network parameter auto-configuration function is used in the deployment of the cloning images, the "Physical Server Name"set in th

Strona 232

5. Change [Admin LAN (IP address)].6. Click <OK>.The admin IP address of the managed server is changed. NoteIt is not possible to change IP add

Strona 233

2. In the ROR console server resource tree, right-click the target chassis and select [Modify]-[Registration Settings] from thepopup menu.The [Modify

Strona 234

1. Change the remote server management settings.If the user account is changed, it should still have administrator authority.2. In the ROR console ser

Strona 235 - Appendix C Maintenance Mode

If the login account information (user ID and password) of the VM host entered when the VM host was registered is changed, change thelogin account inf

Strona 236 - Glossary

9.1.11 Changing Admin LAN SubnetsUse the following procedure to change an admin LAN subnet.1. From the ROR console menu, select [Settings]-[Admin LAN

Strona 237

Abbreviation ProductsOracle Enterprise LinuxOracle Enterprise Linux Release 5 Update 4 for x86 (32 Bit)Oracle Enterprise Linux Release 5 Update 4 for

Strona 238

9.2.1 Changing the IP Address of the Admin ServerThis section explains how to change the IP address of the admin server.When this setting is changed,

Strona 239

2. To use this feature, the following settings must first be defined:User IDEnter the ID of a VIOM user account.PasswordEnter the password of the abov

Strona 240

If the IP address of the target switch is set to the same address as that of another unregistered LAN switch unintentionally, changeback the target LA

Strona 241

Physical Port, Link AggregationSelect [Untagged] from the VLAN type of the port number to configure or link aggregation group name.3. Click <OK>

Strona 242

Deleting VLAN IDsThis section explains how to delete VLAN IDs.- Deleting VLAN IDs from LAN switch bladesUse the following procedure to delete VLAN IDs

Strona 243

1. In the ROR console management software tree, right-click the target management software, and select [Modify]-[RegistrationSettings] from the popup

Strona 244

Data storage periodEnter storage periods for each collection rate. Data older than the configured storage period will be deleted every day.Enlarging d

Strona 245

9.7 Changing Monitoring Information SettingsThis section explains how to change and cancel monitoring information settings.9.7.1 Changing Monitoring

Strona 246

2. Modify the values for the following items:LabelEnter up to 32 alphanumeric characters or symbols.CommentsEnter up to 256 alphanumeric characters or

Strona 247

3. Click <OK>.The basic information of the virtual storage resource is modified.9.8.4 Changing Disk Resource Basic InformationThis section expl

Komentarze do niniejszej Instrukcji

Brak uwag