Fujitsu ServerView Resource Orchestrator Cloud Edition J2X Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Akcesoria komputerowe Fujitsu ServerView Resource Orchestrator Cloud Edition J2X. FUJITSU ServerView Resource Orchestrator Cloud Edition J2X1-7611-03ENZ0 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 223
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - Operation Guide

J2X1-7611-05ENZ0(03)March 2013Windows/LinuxServerView Resource Orchestrator Cloud Edition V3.1.1Operation Guide

Strona 2

- ServerView and Systemwalker are registered trademarks of FUJITSU LIMITED.- All other brand and product names are trademarks or registered trademarks

Strona 3 - Organization

Execute the rcxmgrbackup command.Periodically executing the rcxmgrbackup command allows the contents of updates to the database that are recorded in s

Strona 4 - Notational Conventions

2. To manage tasks hierarchically, use the following procedure to create a folder:a. In the Task Scheduler menu, after selecting Task Scheduler Librar

Strona 5

PointWhen using the Create Basic Task Wizard, execution for a time interval shorter than one day cannot be set, so once the task has beenregistered

Strona 6

15. Open the Triggers tab, select the existing trigger, and click the Edit button.16. Check the [task every:] checkbox in [Advanced settings], and sel

Strona 7

[Windows Manager]In value, specify the number of stored generations that were saved at backup.>Installation_folder\SVROR\Manager\bin\rcxadm imagemg

Strona 8

[Windows Manager]>Installation folder\SWRBAM\CMDB\FJSVcmdbm\bin\cmdbrefresh.exe -a -q <RETURN>[Linux Manager]# /opt/FJSVcmdbm/bin/cmdbrefresh

Strona 9

1. Create a new backup directory.[Windows Manager]> D: <RETURN>> cd \ <RETURN>> mkdir basebackup\Charging <RETURN>> E: &

Strona 10

/var/opt/FJSVctchg/pgsql/data/postgresql.conf- Setting before Changearchive_command = 'cp "%p" "/var/opt/FJSVctchg/backup/wal/%f&q

Strona 11 - Contents

Starting the ManagerStart the manager.For details on how to start the manager, refer to "2.1 Starting and Stopping the Manager".10.2 Backup

Strona 12

- When performing automatic configuration of network devices- When executing the rcxadm netdevice cfbackup command specifying the network device Poin

Strona 13

ContentsPart 1 Overview...

Strona 14

SeeFor details on the rcxadm netdevice command, refer to "3.8 rcxadm netdevice" in the "Reference Guide (Command/XML) CE".- 96 -

Strona 15 - Part 1 Overview

Part 4 MonitoringChapter 11 Monitoring Resources...

Strona 16 - Monitoring

Chapter 11 Monitoring ResourcesThis chapter explains how to monitor the configuration and status of managed resources.11.1 OverviewResource Orchestrat

Strona 17 - Administrators

Table 11.2 List of Regularly Updated Resources and Their Related ResourcesResources Subject to Regular Update Related Resources Data SourceChassis Cha

Strona 18

Table 11.3 Resource IconsIcon MeaningServer resourceChassisServerPhysical OSVM hostVM guestLAN switch bladeL2 switchFirewallServer load balancerIntegr

Strona 19 - Part 2 Operation

Note- On the SPARC Enterprise T series, as statuses cannot be obtained from ILOM using SNMP, only "normal", "stop" or "unkno

Strona 20 - - Related Services

- For network devices, only "normal" and "unknown" are displayed.11.3 Addressing Resource FailuresThis section explains how to add

Strona 21 - - Database (PostgreSQL)

- Detection of changes in state by software for network managementAn infrastructure administrator checks the status of the network device and takes co

Strona 22

- When the network device on which a change in state occurs is something other than a firewall and a server load balancera. Confirm the name of the ne

Strona 23

- When the network device on which the change in state has occurred is a server load balancerConfirm the status of the server load balancer.For detail

Strona 24 - - Agent Service

8.5.5.2 How to Modify Application Process to be Used...

Strona 25

- Configuration files for interfaces- When it is possible that the hardware has failed, in cases where the firewall device status is "unknown&quo

Strona 26 - Chapter 4 Managing Tenants

b. Confirm the name of the L-Platform using the firewall by checking the items in displayed results of the rcxadm firewall showcommand (L-Platform Nam

Strona 27 - Chapter 5 Managing Templates

- Scripts for configurations- Parameter files- Configuration files for interfacesFurther, confirm that the server to be load balanced is operating nor

Strona 28 - 6.3 Managing L-Servers

4. Identify the L-Platform in use.a. Confirm the name of the server load balancer allocated using auto-configuration by checking the items displayed i

Strona 29

5. Take corrective action based on the results of checked scripts and files.- When there are no errors in the scripts or settings in files checked in

Strona 30 - 7.2.3.3 Releasing L-Servers

- For EMC CLARiiON storageRefer to the "EMC Navisphere Manager Administrator's Guide".- For EMC Symmetrix DMX storage and EMC Symmetrix

Strona 31

Chapter 12 Collecting Power Consumption Data andDisplaying GraphsThis chapter explains how to export the power consumption data collected from registe

Strona 32

- TimeThis column displays the date and time at which each data sample was collected.Within data lines, the entry corresponding to this column is disp

Strona 33 - 7.2.8 Redundancy Settings

Chapter 13 Monitoring Resource Pools (Dashboard)This chapter explains how to monitor resource pools.Use the [Dashboard (Pool Conditions)] tab of the R

Strona 34

Chapter 14 Monitoring L-PlatformsThis chapter explains how to monitor L-Platforms.The operation status of L-Servers can be monitored from the [Dashboa

Strona 35 - Chapter 8 Changing Settings

10.1.4.2 Restoring the Resources of This Product...

Strona 36

Chapter 15 AccountingThis chapter explains the accounting.15.1 OverviewThis section explains an overview of the accounting.This function provides the

Strona 37

[Management and operation of accounting information by the infrastructure administrator]1. The infrastructure administrator registers L-Platform templ

Strona 38 - Port number

NoteUsage fee (the estimated price) for the L-Platform template will be displayed provided that settings for the estimated price display functionare

Strona 39

the existing disk capacity will be added together in accordance with the number of L-Servers to which the disk is attached. Resourceallocation methods

Strona 40

L-Platform usage fee (the estimated price) = monthly template price + monthly price for all L-Server + monthly price for all system

Strona 41

Physical L-Server monthly price = image unit price * converted monthly converted +(CPU unit price * monthly converted price

Strona 42

No Name Omit Explanation- memory: memory capacity- vm: virtual L-Server- pm: physical L-Server- sys_disk: system disk capacity- disk: extension disk c

Strona 43 - 4. Restart the manager

- The unit price for product ID "ME-0001" is $1.00 on 2011-08-15 because data B has higher priority even though both data A anddata B are in

Strona 44 - Template

... </vdisk> </vdisks> <image>

Strona 45

It is also possible to modify accounting information for L-Servers that were imported into the system.Refer to "15.3.2 Modify Accounting Informat

Strona 46

15.4.6.2 Usage charge Detail File...

Strona 47

7. Enable the L-Platform template.Enable the L-Platform template on the start of applicable date. Refer to "8.3.6 Publishing and Hiding L-Platfor

Strona 48 - 8.7 Accounting Settings

15.3.2 Modify Accounting InformationModify the accounting information of the L-Platform templates that are already enabled. This corresponds to the ca

Strona 49

- Priority: Higher priority than the existing data A- Unit price: New unit price- Start of applicable date: Start date of the period- End of applicabl

Strona 50 - 8.7.3 Metering Log Settings

Check Metering Log1. Check that the log that shows the usage result of the corresponding L-Platform templates does not exist in the metering log.Outpu

Strona 51

(Product Master Maintenance)" in the "Reference Guide (Command/XML) CE" for information on the output function of the productmaster mai

Strona 52

15.4.3 How to Charge for ResourcesResources can be charged by a fixed rate or by the amount used. With fixed charging, the usage charges are charged a

Strona 53

PointUsage Charges for physical L-Servers.The calculation of Usage Charges for the CPU, CPU clock, and memory capacity of the physical L-Server are c

Strona 54

Resource Resource identifier Unit codes Unit pricecpu /VMPool hour $0.001cpu_clock /VMPool hour $0.002memory /VMPool hour $0.001sys_disk /StoragePool

Strona 55

PointFractions in usage chargesWhen the calculations of usage charge produce a figure that includes fractions less than the lowest unit in the curre

Strona 56 - Part 3 Retention

L-Platform transfersWhen an L-Platform is moved, the usage charges for resources charged by amount are divided between the departure tenant and destin

Strona 57 - 9.1 Overview

Part 1 OverviewChapter 1 Overview of Operations, Maintenance, and Monitoring...2- 1 -

Strona 58

Item DescriptionFormat:ZZZZZZZZZZZ9 (*2)Example:800FileVersion This is the version of the file.Fixed as 1.0.LplatformId This is the L-Platform ID. (*1

Strona 59

Item DescriptionChargeAmount The amount of usage charges for each L-Platform.The amounts are values, so they are not enclosed with double-quotes (&quo

Strona 60

"","","","","","","",,"","Physical server(pserverA)","C

Strona 61 - - Replacing Server Components

Chapter 16 Monitoring LogsThis chapter explains how to monitor logs.16.1 Operation LogsThis section explains the operation logs of Resource Orchestrat

Strona 62 - 9.2 Blade Server Maintenance

Element Name Description RemarksStarting(Operation_identifier)- End of operationsCompleted(Operation_identifier)- Errors during operationsError(Operat

Strona 63

2011-03-10 23:42:37.171 admin - 10.20.30.53 Starting(BX620-1_40) BX620-1_578(image_test) server_images destroy2011-03-10 23:42:47.460

Strona 64 - 9.2.3 Replacing Servers

16.1.2 Usage MethodThis section explains the methods for configuring and operating operation logs.Perform the following procedure:1. Disk space estima

Strona 65

16.1.3 RetentionThis section explains the retention of operation logs.- Periodic deletionDue to extended periods of operation or modification of reten

Strona 66

- Performing this procedure resets the recording period of operation logs to 0.16.1.4 Scope of Operations Recorded in Operation LogsThe scope of opera

Strona 67

The file name, file size, and number of generations of the audit log are shown below: Log name Description File sizeNumber ofgenerationsvsys_audit_log

Strona 68

Chapter 1 Overview of Operations, Maintenance, andMonitoringThis chapter provides an overview of operation, maintenance, and monitoring of Resource Or

Strona 69 - 9.3.2 Replacing Servers

Item Descriptionoperation result "SUCCESS" if the operation was successful and "FAILURE" if the operation failed.* Note: The opera

Strona 70

Operation type DescriptionTemplates#getDetail Obtaining detailed L-Platform template information.Templates#importPublic Registering L-Platform templat

Strona 71

Operation type DescriptionVSYS#flowRejectApplication Rejecting deployment application.VSYS#flowRelease Returning all L-Platforms as a batch. (For flow

Strona 72

Operation type DescriptionVSYS#update Reconfiguring an L-Platform.VSYS#updateLNetDev Updating the parameters for the firewall and server load balancer

Strona 73

Log name Settings file Location to change (one location)Example: value="100MB" (to change the size of theaudit log file to 100 MB)2. Restart

Strona 74

[Linux Manager] /opt/fujitsu/ServerViewSuite/opends/logs/accessRefer to the OpenDS website for details on OpenDS access logs. URL: https://docs.opends

Strona 75

Function Output fileAccounting(GUI operations fromthe ROR Console)[Windows Manager]Installation_folder\RCXCTMG\Charging\log\charging_audit.log[Linux M

Strona 76 - - For Physical L-Servers

Function Definition fileAccounting(GUIoperationsfrom the RORConsole)[Windows Manager]Installation_ folder\RCXCTMG\conf\auditchgguilog4j.xml[Linux Mana

Strona 77

Function Operation type Content Operation information (*1)(only if the infrastructure administrator performed or the tenantadministrator performed by

Strona 78

Function Operation type Content Operation information (*1)tenant,workflow.reconfigure=infra-tenant|infra|tenant ,workflow.unsubscribe=infra-tenant|inf

Strona 79

5. Configure firewallsWhen configuring an application on an L-Server that has been deployed on the public LAN, the tenant user needs to create a rulet

Strona 80

Function Operation type Content Operation information (*1)registerUsagePointRegister usagefrequency (*4)"date=""<date of data regist

Strona 81

Installation_folder\SWRBAM\bin\swrba_auditThe process instance audit information that can be obtained will be the process instance information that wa

Strona 82

Item DescriptionProcess instance nameProcess instance nameL-PlatformSubscription_xxx,L-PlatformChange_xxx,L-PlatformUnsubscription_xxxState of process

Strona 83

16.3 Operation Logs (Activity)This section explains operation logs.Operation logs are used as maintenance information when investigating and dealing w

Strona 84

Output DestinationThe log output destinations are shown below:[Windows Manager] Output folder Output destination fileInstallation_folder\RCXCFMG\logs

Strona 85

Log name Settings file Location to change (one location)vsys_batch_logInstallation_folder\RCXCFMG\config\batch_log4j.xml<param name="File"

Strona 86 - Network Devices

Part 5 High Availability and DisasterRecoveryChapter 17 High Availability of Managed Resources...

Strona 87

Chapter 17 High Availability of Managed ResourcesThis chapter explains failover.17.1 High Availability of Managed ResourcesThis section explains how t

Strona 88

- Number of NICsCheck the number of NICs mounted on a compatible server and L-Server.A server is considered as a server satisfying the conditions, in

Strona 89

Definition File FormatFor the definition file, write each line in the following format: Key = ValueWhen adding comments, start with a number sign (&qu

Strona 90

- Create a tenant administrator- Creation, modification, and deletion of user accounts- Management of templates- Creation, modification, and deletion

Strona 91

| errorOVERALL_POLICY=skip# Server model compatibility listSPARE_SVR_COMPAT0=["BX920 S1", "BX920 S2"]17.1.2 Blade Chassis High Ava

Strona 92

3. Check if the status of the L-Server that is the source for switchover is stop.If the status of the L-Server is not stop, stop the L-Server.The L-Se

Strona 93

3. Start the L-Server.For details on how to start an L-Server, refer to "17.1.1 Starting an L-Server" in the "User's Guide for Inf

Strona 94

Replication Definition FilesThe replication definition file must be created in advance. In the replication definition file, describe the relationship

Strona 95

- For EMC Symmetrix DMX storage and EMC Symmetrix VMAX storageThe relationship for replication can be checked using the SRDF function.Specify SymmID f

Strona 96

6. Execute the failover script on the server where the manager is being operated.- If the error message number 62513 occurs during script executionThe

Strona 97 - 10.1.2.3 Starting the Manager

6. Create the following scripts by executing the rcxstorage -failback command.- failback script- Physical L-Server stopping script- Physical L-Server

Strona 98

14. When operating an L-Platform, use the cfmg_syncdiskinfo command to reflect the information for switched disks on the L-Platformconfiguration infor

Strona 99

Manager High Availability in Windows Guest Environments in Hyper-V environments- Install an operating system and configure a domain controller on the

Strona 100

Note- When performing configuration, modification, or deletion of managed server environments, such as L-Server creation, if an erroroccurs on VM gue

Strona 101 - Example

Part 2 OperationChapter 2 Starting and Stopping Managers and Agents...

Strona 102

Note- If switchover of an admin server occurs while L-Servers are operating, the operation being performed may fail.If you were creating or registeri

Strona 103 - 10.1.4.1 Stopping the Manager

Chapter 18 Disaster RecoveryThis chapter provides information on Disaster Recovery for the admin server where Resource Orchestrator manager operates.R

Strona 104 - 10.1.4.3 Starting the Manager

Appendix A Notes on Operating ServerView ResourceOrchestratorThis appendix provides important reminders for the operation of Resource Orchestrator. R

Strona 105

Parameter Meaning Initial Value- When restartingSpecify "true".- When not restartingSpecify "false".RESTART_HOURSpecify the restar

Strona 106

Item Key Value RemarksOperates by default, when there are nodefinition files.Example Definition FileAn example definition file is indicated below. In

Strona 107

Multiplicity Increase in Memory Use (Unit: MB)6 - 14 1080 + (Multiplicity * 40)15 - 30 2104 + (Multiplicity * 40)- 181 -

Strona 108 - Starting the Manager

Appendix B Metering LogThis chapter explains the metering log.Metering logs is saved in the database as Information based on bill calculations so tha

Strona 109

Event Event identifier Timing of event Resource- L-Platform template (*2)- Software*1: If the timing of output of the periodic log is to be changed, o

Strona 110

Item ID Output for each event Item name DescriptionADD CHANGEDELETESTART STOP PERIODevent Yes Yes Yes Yes Yes Yes Event ADD: DeployCHANGE: ChangeDELET

Strona 111 - Part 4 Monitoring

Item ID Output for each event Item name DescriptionADD CHANGEDELETESTARTSTOP PERIODvsys_id Yes Yes Yes Yes Yes Yes L-Platform ID ASCII: 1 to 32 charac

Strona 112 - 11.1 Overview

Preface Resource Orchestrator Documentation Road MapThe documentation road map for Resource Orchestrator is as shown below.Resource Orchestrator Docum

Strona 113 - 11.2 Resource Status

Chapter 2 Starting and Stopping Managers and AgentsThis chapter explains how to manually start or stop managers and agents.To use Resource Orchestrato

Strona 114 - Table 11.4 Status Icons

Item ID Output for each event Item name DescriptionADD CHANGEDELETESTART STOP PERIODorg_id Yes Yes Yes Yes Yes Yes Tenant name ASCII: 1 to 32 characte

Strona 115 - Information

DiskIn addition to the common items output, the following items will be output: Item ID Output for each event Item name DescriptionADD CHANGE DELETE

Strona 116 - 11.4 Monitoring Networks

Item ID Output for each event Item name DescriptionADD CHANGE DELETE PERIODorg_id Yes Yes Yes Yes Tenant name ASCII: 1 to 32 charactersName of the te

Strona 117

No. Item ID Item name Data type8 status Status String9 user_id User account String10 server_id L-Server ID String11 disk_id Disk ID String12 software_

Strona 118

verId001","","softwareId001","systemName001","","","","","","

Strona 119

- If snapshot restore has been performed, an event log with CHANGE as the event will be output even if there was no change.- At execution of the Impor

Strona 120

Glossary access pathA logical path configured to enable access to storage volumes from servers. active modeThe state where a managed server is perform

Strona 121

Auto-RecoveryA function which continues operations by automatically switching over the system image of a failed server to a spare server andrestarting

Strona 122

CCM (ETERNUS SF AdvancedCopy Manager Copy Control Module)This is a module that does not require installation of the ETERNUS SF AdvancedCopy Manager ag

Strona 123

end host modeThis is a mode where the uplink port that can communicate with a downlink port is fixed at one, and communication between uplinkports is

Strona 124 - 11.5 Monitoring Storage

PXE ServicesDHCP Server (*)Systemwalker SQC DCMInterstage BPM Analytics eRule Engine (EFServer)Systemwalker MpJobsch9Systemwalker MpMjesSystemwalker M

Strona 125 - - For NetApp storage

FTVThe virtual volumes created by Automatic Storage Layering for ETERNUS.In Resource Orchestrator, FTVs are used as disk resources on which Thin Provi

Strona 126 - Displaying Graphs

IBP (Intelligent Blade Panel)One of operation modes used for PRIMERGY switch blades.This operation mode can be used for coordination with ServerView

Strona 127

iSCSI storageStorage that uses an iSCSI connection. LAG (Link Aggregation Group)A single logical port created from multiple physical ports using link

Strona 128

LUN (Logical Unit Number)A logical unit defined in the channel adapter of a storage unit. MAC address (Media Access Control address)A unique identifie

Strona 129

- Cold migrationMigration of an inactive (powered-off) VM guest.- Live migrationMigration of an active (powered-on) VM guest. multi-slot serverA serve

Strona 130 - Chapter 15 Accounting

OSThe OS used by an operating server (a physical OS or VM guest). overcommitA function to virtually allocate more resources than the actual amount of

Strona 131

primary serverThe physical server that is switched from when performing server switchover. primary siteThe environment that is usually used by Resour

Strona 132 - - CPU: $0.80/unit

- For Dell/IBM serversBMC (Baseboard Management Controller) Remote Server ManagementA PRIMEQUEST feature for managing partitions. Reserved SBIndicates

Strona 133

The script lists contain the scripts used to perform automatic configuration.There are the following eight types of script lists:- script lists for se

Strona 134

ServerView Update Manager ExpressInsert the ServerView Suite DVD1 or ServerView Suite Update DVD into the server requiring updating and start it.This

Strona 135

For details on the command, refer to "5.19 rcxmgrctl" in the "Reference Guide (Command/XML) CE".To start or stop a manager in a cl

Strona 136

switchover stateThe state in which switchover has been performed on a managed server, but neither failback nor continuation have been performed. syste

Strona 137

Example\\hostname\dir_name UPS (Uninterruptible Power Supply)A device containing rechargeable batteries that temporarily provides power to computers

Strona 138

Using a Virtual LAN, network configuration can be performed freely without the need for modification of the physical networkconfiguration. VLAN IDA nu

Strona 139

WWNN (World Wide Node Name)A name that is set as a common value for the Fibre Channel ports of a node. However, the definitions of nodes vary betweenm

Strona 140

- Agent ServiceResource Coordinator Agent- Related Services- Deployment Agent- Systemwalker SQC DCMFrom the Windows Control Panel, open [Administrativ

Strona 141

# /etc/init.d/scwagent start <RETURN># /etc/rc2.d/S99ssqcdcm start <RETURN>Stop # /etc/init.d/scwagent stop <RETURN># /etc/rc0.d/K00

Strona 142

Chapter 3 Managing User AccountsThis chapter explains the management of user accounts. Creation, Viewing, and Modification of User AccountsOnly users

Strona 143

Chapter 4 Managing TenantsThis chapter explains the management of tenants. Tenant CreationThe flow of tenant creation is as follows:1. Register Tenant

Strona 144 - 15.4.2 Resource Usage Times

Chapter 5 Managing TemplatesThis chapter explains the management of templates.- L-Platform TemplatesAn L-Platform template is the template to define t

Strona 145

Chapter 6 Managing Resources and Resource PoolsThis chapter explains the management of resources and resource pools.6.1 Managing Resource PoolsThis se

Strona 146 - Charge information

Chapter 7 Management of L-PlatformThis chapter explains how to management of L-Platform.7.1 Review for L-Platform Usage ApplicationsUse the [Request]

Strona 147

PurposeThis manual explains how to operate ServerView Resource Orchestrator (hereinafter Resource Orchestrator). Target ReadersThis manual is written

Strona 148 - Fractions in usage charges

c. Importing the L-Server for which network information has been setRefer to "7.2.3.2 Importing L-Servers".- Import L-Servers created in the

Strona 149 - 15.4.6 Sending Usage charges

is completed.When a deployment finishes, the IP address and host name of the guest OS are the same values as the server from which the cloning imageha

Strona 150

- Configuration or modification of network devices such as firewalls or server load balancersFigure 7.1 Flow of Corrective Actions when a Problem Occu

Strona 151

For information on creating L-Server templates, refer to "Chapter 15 L-Server Template Operations" in the "User's Guide for Infras

Strona 152

- L-Server template name where automatic server release settings are enabledVMware_Small_Repurpose7.2.10 Definition VM Specific Information Definition

Strona 153 - Chapter 16 Monitoring Logs

Chapter 8 Changing SettingsThis chapter explains how to change settings.8.1 Registering and Deleting Application Process AssessorsThis section explain

Strona 154

# Delete manager from IflowUsersdn: cn=IflowUsers,ou=group,dc=fujitsu,dc=comchangetype: modifydelete: membermember:cn=manager,ou=users,dc=fujitsu,dc=c

Strona 155

Settings for the Email Sent from Tenant ManagementEmail sent from the tenant management will be enabled only if the tenant has set the Performing tena

Strona 156 - 16.1.2 Usage Method

1. Modify the portal.properties file.Open the following file:[Windows Manager]Installation_folder\RCXCTMG\SecurityManagement\conf\portal.properties[Li

Strona 157 - 16.1.3 Retention

2. Modify the managerview_config.xml file.Open the following file.[Windows Manager]Installation_folder\RCXCTMG\MyPortal\config\managerview_config.xml[

Strona 158 - 16.2 Audit Logs

Chapter 12 Collecting Power Consumption Data and Displaying GraphsExplains how to export the power consumption data collected from registered power mo

Strona 159 - Installation_folder

- Enter a string of up to 30 characters for the schedule. Commas (,) cannot be included.- Enter a string of up to 250 characters for the message. Comm

Strona 160

8.5.2 Subnet Settings at Segment EditingIt is possible to change the method for setting up the subnets that are allocated to segments when performing

Strona 161

[Linux Manager]/etc/opt/FJSVctmyp/config/managerview_config.xml2. Add the following key and value: Key name Contentenable-easy-reconfigure false: Disa

Strona 162

4. Restart the manager.Refer to "2.1 Starting and Stopping the Manager" for information on how to restart the manager.8.5.5 Application Pro

Strona 163

8.5.10 Settings for the Maximum Number of Connections for the L-PlatformTemplateThe maximum number of L-Servers that can be placed in an L-Platform Te

Strona 164 - Control and System Condition

8.6.1 Settings for Tenant Management and Account ManagementThis section explains how to change the settings for the tenant management and the account

Strona 165

/etc/opt/FJSVctsec/conf/portal.properties2. The following information must be modified: Setting item Settingsvisible.tenantuser Setting for infrastruc

Strona 166

Setting item Settingsuser password button will not bedisplayed in the Account window of theaccount management.leftMenu.modifyUser.user.visible Setting

Strona 167

Setting item SettingsIf "false" has been specified, the Setpassword button will not be displayed inthe User List window of the tenantmanagem

Strona 168

/etc/opt/FJSVcfmg/config/vsys_config.xml2. The following information must be modified: Key Description Default valueuse-charge (*) Specifies whether u

Strona 169

[OVM for x86] Sections related to Oracle VM Server for x86[OVM for SPARC] Sections related to Oracle VM Server for SPARC[Physical Servers] Sections re

Strona 170

software is used, the usage fee (the estimated price) will be calculated using the operating value regardless of whether or notovercommit is enabled o

Strona 171 - Process instance starter

2. Change the relevant items in the operational settings file for metering logs: Key Description Default valueretention_period Retention period of log

Strona 172

Key Description Default valueA number of days cannot be specified with thismethod.*1: Changes to this setting are enabled by executing the Change peri

Strona 173 - 16.4 Investigation Logs

Key Description Default valueaccounting.use (*) Specify whether to use the usage chargecalculator.- yes: Use the usage charge calculator.- no: Do not

Strona 174

If the L-Platform Management overcommit function is enabled, the CPU and memory settings displayed in the System Condition ServerList can be changed.

Strona 175 - 2. Restart the manager

- When editing the viewlist_en.xml file, do not change any settings items other than serverByOrg_ROR.bottom.column.11.isEnableand serverByOrg_ROR.bott

Strona 176 - Recovery

Part 3 RetentionChapter 9 Hardware Maintenance...

Strona 177

Chapter 9 Hardware MaintenanceThis chapter explains how to perform hardware maintenance.9.1 OverviewThis section explains how to perform maintenance o

Strona 178

- For SPARC M10The infrastructure administrator places the managed servers into maintenance mode.Also place the managed servers into maintenance mode

Strona 179

For details on maintenance mode, refer to "Appendix C Maintenance Mode" in the "User's Guide for InfrastructureAdministrators (Res

Strona 180 - OVERALL_POLICY=skip

Abbreviation ProductsWindowsMicrosoft(R) Windows Server(R) 2012 StandardMicrosoft(R) Windows Server(R) 2012 DatacenterMicrosoft(R) Windows Server(R) 2

Strona 181

2. Investigation RequestThe tenant user requests investigation of the cause of the error by the tenant administrator, based on the information related

Strona 182

Figure 9.3 Flow of Hardware Maintenance when a Server Fails*1: For details on how to identify failures, refer to "11.3 Addressing Resource Failur

Strona 183

- Replacing Non-Server HardwareReplace registered chassis, management blades, or any other hardware components external to servers.For details on repl

Strona 184

2. Click <OK>.The maintenance LED is turned off.9.2.2 Reconfiguration of Hardware PropertiesThis section explains how to reconfigure hardware p

Strona 185

1. After hardware replacement, insert the server and check that the following message is displayed in the event log. Server blade addedAfter the messa

Strona 186

- Replacing a Server with no Spare Server AssignedUse the following procedure to smoothly replace a server and resume its applications.1. Place the Se

Strona 187

For details on BIOS settings, refer to "8.2 Configuring the Server Environment" in the "Design Guide CE".Shut down the server afte

Strona 188

- RBridge ID- Replacing Fibre Channel Switch BladesNo specific action is required in Resource Orchestrator.In Resource Orchestrator, the settings for

Strona 189

To move a server to a different slot within a chassis, the server must be deleted first, and then registered again after being inserted in itsnew slot

Strona 190

NoteWhen registering an agent and performing backups of system images or cloning images, perform one of the following.- Restart the managed server af

Strona 191 - Chapter 18 Disaster Recovery

Abbreviation ProductsRed Hat(R) Enterprise Linux(R) 5.3 (for Intel64)Red Hat(R) Enterprise Linux(R) 5.4 (for x86)Red Hat(R) Enterprise Linux(R) 5.4 (f

Strona 192 - Orchestrator

2. Create a System Image BackupFor local boot servers, create a system image backup when possible.For details on backing up system images, refer to &q

Strona 193

3. Reconfigure Hardware Properties after ReplacementAfter replacing the server, reconfigure Resource Orchestrator with the latest hardware properties.

Strona 194 - Drive_name

3. Perform Post-server Switchover OperationsFor details on the operations that must be performed after server switchover, refer to "4.3 Post-Swit

Strona 195 - Multiplicity

4. Perform Post-server Switchover OperationsFor details on the operations that must be performed after server switchover, refer to "4.3 Post-Swit

Strona 196 - Appendix B Metering Log

2. Replace the ServerReplace the server.Use the Maintenance Wizard of the Management Board Web-UI to perform replacement.For details on the Maintenanc

Strona 197

- When using I/O virtualization, the replacement HBA will automatically inherit the WWN originally set on the replaced HBA.Therefore, there is no need

Strona 198

When replacing an entire server, a CPU, or memory, if there are differences in the CPU or memory specifications before and after thereplacement, refle

Strona 199 - Physical L-Server

Figure 9.4 Image of Network Device ReplacementIt is assumed that you perform replacement while continuing operations using the network devices of redu

Strona 200

When the Management Function for Network Device Configuration Files is Used1. Announcement of planned maintenance operations.2. Change the target net

Strona 201

3. Change the target network device to "maintenance mode".4. Back up the current environment (such as definitions) from the network devices

Strona 202

Abbreviation ProductsRed Hat(R) Enterprise Linux(R) 5.8 (for x86)Red Hat(R) Enterprise Linux(R) 5.8 (for Intel64)Red Hat Enterprise Linux 6Red Hat(R)

Strona 203

automatically.For details, please refer to the manual of the "Cisco ASA 5500 series".- For restoration of network device files, please refer

Strona 204

- When the network device to replace has failed, step 4 cannot be performed. It is recommended to back up environments regularly inpreparation for fai

Strona 205 - B.4 Deleting Metering Logs

9. Switch over the network device in active status that is the target of regular maintenance and the network device of the redundancyconfiguration whi

Strona 206 - Glossary

Figure 9.5 Image of L2 Switches to Add1. Design additional configurations. (Network device administrator)2. Provide the additional network device info

Strona 207

6. When the following applies to the additional network device, create and register rulesets.- When adding an L2 switch of a model for which sample sc

Strona 208

Figure 9.6 Image of Tenants to Add1. Design additional configurations. (Network device administrator)2. Provide the additional network device informat

Strona 209

5. Register the added firewall, server load balancer, and L2 switch as network devices.Use the rcxadm netdevice create command to register as a networ

Strona 210

2. Create network configuration information (XML definition) using the acquired network device information.3. Confirm there are no differences besides

Strona 211

3. Reconfigure the power monitoring device's hardware properties.a. In the ROR console server resource tree, right-click the target power monitor

Strona 212

Chapter 10 Backup and RestorationThis chapter describes how to operate the backup and restoration of ServerView Resource Orchestrator Cloud Edition.10

Strona 213

Abbreviation ProductsVMware DRS VMware(R) Distributed Resource SchedulerVMware DPM VMware(R) Distributed Power ManagementVMware vDS VMware(R) vNetwork

Strona 214

Usually, for each 16 MB written, the WAL file being written to is switched, and the WAL file for which writing has been completedis saved to the "

Strona 215

- Do not delete backup resources during execution of the restore command.- To delete backup resources, delete the folder specified in the backup desti

Strona 216

Target Resources When Backup is NecessaryNecessity ofStoppingManagersRemarksDefinition files Modification of definition files No (Note)Note) If the fo

Strona 217

Target Resources Disk Space Necessary for the BackupSystem image or cloning imageEvery time, when backing up, it is necessary. Therefore, when theback

Strona 218

* Note: The backup of metering information is gathered under the control of the directory specified by the rcxmgrbackup command at anoff-line backup,

Strona 219

Table 10.7 Disk Space Necessary for Operation of Online BackupDisk space necessary for operation of online backup= Disk space necessary for base backu

Strona 220

- Command processing time- offline backup : 3 minutes- online backup (base backup) : 2 minutes- online backup (differential backup) : 2 minutes- resto

Strona 221

10.1.2.1 Stopping the ManagerStop the Manager and check that it is in a stopped state. Stopping the ManagerExecute the command shown below to stop the

Strona 222

Saving Image Management InformationCheck the following image management information, the number of stored snapshot generations and the image file stor

Strona 223

NoteThe backup command may not end normally at times, so do not perform the following operations:- Forced end using Ctrl+C during execution of the ba

Komentarze do niniejszej Instrukcji

Brak uwag